摘要
A novel electrochemical cell for capillary electrophoresis with end-column amperometric detection is described. A platinum microdisk electrode (d(Pt) = 25 mu m) facing the capillary outlet served as sensing electrode. The problem of interference of the high voltage electrical field with the microelectrode circuit has been solved by the construction of a glass sleeve/Nafion joint for 100 mu m i.d. capillaries. With 25 mu m i.d. capillaries end-column detection could be performed without the use of an electrical-field decoupler arrangement. The analytical performance of the detector was characterized applying capillary zone electrophoresis and micellar electrokinetic capillary chromatography to separate various ferrocene derivatives. In addition, the same detector cell configuration has been used for amperometric detection in conjunction with capillary flow injection analysis.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 24 条
[1]   MULTICHANNEL ELECTROCHEMICAL DETECTION WITH A MICROELECTRODE ARRAY IN FLOWING STREAMS [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :44-49
[2]   AMPEROMETRIC DETECTION OF PICOMOLE SAMPLES IN A MICRODISK ELECTROCHEMICAL FLOW-JET CELL WITH DILUTE SUPPORTING ELECTROLYTE [J].
BIXLER, JW ;
BOND, AM .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2859-2863
[3]   CAPILLARY ELECTROPHORESIS WITH AMPEROMETRIC DETECTION USING A POROUS CELLULOSE-ACETATE JOINT [J].
CHEN, IC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :208-212
[4]   ELECTROCHEMICAL DETECTION FOR CAPILLARY ELECTROPHORESIS [J].
CURRY, PD ;
ENGSTROMSILVERMAN, CE ;
EWING, AG .
ELECTROANALYSIS, 1991, 3 (07) :587-596
[5]  
Fleischmann M, 1987, ULTRAMICROELECTRODES
[6]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[7]   SOLID-STATE FIELD DECOUPLER FOR OFF-COLUMN DETECTION IN CAPILLARY ELECTROPHORESIS [J].
KOK, WT ;
SAHIN, Y .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2497-2501
[8]   ELECTROOSMOTICALLY PUMPED CAPILLARY FLOW-INJECTION ANALYSIS - VALVE-BASED INJECTION SYSTEMS AND SAMPLE THROUGHPUT [J].
LIU, SR ;
DASGUPTA, PK .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :739-745
[9]   FLOW-INJECTION ANALYSIS IN THE CAPILLARY FORMAT USING ELECTROOSMOTIC PUMPING [J].
LIU, SR ;
DASGUPTA, PK .
ANALYTICA CHIMICA ACTA, 1992, 268 (01) :1-6
[10]   END-COLUMN ELECTROCHEMICAL DETECTION FOR INORGANIC AND ORGANIC-SPECIES IN HIGH-VOLTAGE CAPILLARY ELECTROPHORESIS [J].
LU, WZ ;
CASSIDY, RM ;
BARANSKI, AS .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :433-440