DETERMINATION OF SULFITE IN WINE BY FLOW-INJECTION ANALYSIS WITH INDIRECT ELECTROCHEMICAL DETECTION

被引:33
作者
THANH, NTK [1 ]
DECNOPWEEVER, LG [1 ]
KOK, WT [1 ]
机构
[1] UNIV AMSTERDAM,ANALYT CHEM LAB,NIEUWE ACHTERGRACHT 166,1018 WV AMSTERDAM,NETHERLANDS
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1994年 / 349卷 / 06期
关键词
D O I
10.1007/BF00322936
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection method has been developed for the determination of total sulphite in wine samples. After hydrolysis of bound sulphite, sulphur dioxide is separated from the matrix by means of an in-line gas diffusion module. For detection indirect amperometry is used, with iodine as oxidizing reagent. The iodine can be generated in-line by merging and mixing iodate and iodide solutions, or alternatively, electrochemically from iodide. With the latter method the best results were obtained. The reproducibility of the peak heights is better than 2%. The linear range of the method can be regulated by adaptation of the current applied to generate the iodine reagent. Due to the low detection limits obtained (0.05 mg L-1), wine samples can be strongly diluted before injection, which makes the sample pretreatment fast and simple. Good agreement has been found with the results obtained for the total sulphite concentration in different wine samples by titration.
引用
收藏
页码:469 / 472
页数:4
相关论文
共 19 条
[1]  
[Anonymous], 1984, OFFICIAL METHODS ANA
[2]   DETERMINATION OF TOTAL AND FREE SULFUR-DIOXIDE IN WINE BY FLOW-INJECTION ANALYSIS AND GAS-DIFFUSION USING PARA-AMINOAZOBENZENE AS THE COLORIMETRIC-REAGENT [J].
BARTROLI, J ;
ESCALADA, M ;
JORQUERA, CJ ;
ALONSO, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2532-2535
[3]  
Beech F. W., 1979, Bulletin de l'O.I.V., V52, P1001
[4]  
BURGUERA JL, ANAL CHIM ACTA, V214, P429
[5]   IODIMETRIC AND BROMIMETRIC FLOW-INJECTION AMPEROMETRIC METHODS OF DETERMINING SULFITE IN WHICH IODINE OR BROMINE IS MONITORED AT A GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
GUTA, CW ;
CHAMSI, AY .
ANALYST, 1987, 112 (03) :253-258
[6]   OXIDATIVE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF SULFITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
FERNANDEZARCINIEGA, MA ;
ALONSO, RM .
ANALYST, 1985, 110 (07) :851-853
[7]   DETERMINATION OF SULFUR-DIOXIDE BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION [J].
GRANADOS, M ;
MASPOCH, S ;
BLANCO, M .
ANALYTICA CHIMICA ACTA, 1986, 179 :445-451
[8]   DETERMINATION OF CYSTEINE AND N-ACETYLCYSTEINE IN URINE BY LIQUID-CHROMATOGRAPHY WITH INDIRECT AMPEROMETRIC DETECTION [J].
HUANG, XJ ;
KOK, WT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (11) :2207-2221
[9]   DETERMINATION OF SULFITE IN WINE THROUGH FLOW-INJECTION ANALYSIS BASED ON THE SUPPRESSION OF LUMINOL CHEMILUMINESCENCE [J].
HUANG, YL ;
KIM, JM ;
SCHMID, RD .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :317-323
[10]   COMPARISON OF ELECTROCHEMICAL DETECTION METHODS IN LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF N-ACE-TYLCYSTEINE IN PLASMA [J].
KOK, WT ;
HALVAX, JJ ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :27-33