POLY(VINYL CHLORIDE) MATRIX MEMBRANE ELECTRODES FOR MANUAL AND FLOW-INJECTION DETERMINATION OF METAL AZIDES

被引:27
作者
HASSAN, SSM [1 ]
ELZAWAWY, FM [1 ]
MARZOUK, SAM [1 ]
ELNEMMA, EM [1 ]
机构
[1] QATAR UNIV,FAC SCI,DEPT CHEM,DOHA,QATAR
关键词
AZIDE POLY(VINYL CHLORIDE) MEMBRANE ELECTRODE; IRON(II) AND NICKEL(II) BATHOPHENANTHROLINE AZIDE COMPLEXES; POTENTIOMETRIC DETERMINATION OF METAL AZIDES; PRIMER MIXTURE; FLOW INJECTION;
D O I
10.1039/an9921701683
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel poly(vinyl chloride) matrix membrane electrodes for the azide ion are developed, electrochemically evaluated and used for manual and flow injection determinations of soluble and insoluble metal azides. These electrodes incorporate iron(II) and nickel(II) bathophenanthroline-azide ion-pair complexes as ion exchangers and 2-nitrophenyl phenyl ether as a plasticizing solvent mediator. The electrodes exhibit (i) near-Nernstian response for 1 x 10(-1)-3.5 x 10(-5) mol dm-3 N3- with an anionic slope of 56-57 mV decade-1 of concentration; (ii) a wide working range of pH(6-12); (iii) a fast response time (<40s); (iv)long-term stability (>1 month); and (v) reasonable selectivity for N3- over many common anions. Interference caused by ClO4-, ClO3- and NO3- can be easily tolerated by appropriate ion-exchange separation. Determination of as little as 0.8 mug cm-3 of Soluble azides shows an average recovery of 99.4% and a mean standard deviation of 0.4%. Insoluble metal azides can be similarly determined after prior solubilization with alkaline ethylenediaminetetraacetic acid solution. Methods for measuring the solubility products of some sparingly soluble metal azides and for monitoring the concentration level of azide in primer mixtures are described. Significant advantages in terms of simplicity, sensitivity, selectivity and accuracy are offered by these electrodes.
引用
收藏
页码:1683 / 1689
页数:7
相关论文
共 30 条
[1]   SPECTROPHOTOMETRIC DETERMINATION OF AZIDE WITH FERRIC PERCHLORATE [J].
ANTON, A ;
DODD, JG ;
HARVEY, AE .
ANALYTICAL CHEMISTRY, 1960, 32 (09) :1209-1210
[2]   SIMULTANEOUS POLAROGRAPHIC DETERMINATION OF LEAD AND AZIDE IONS OF LEAD AZIDES IN AQUEOUS MEDIA [J].
BRYANT, JI ;
KEMP, MD .
ANALYTICAL CHEMISTRY, 1960, 32 (07) :758-760
[3]  
CAMMANN K, 1977, WORKING ION SELECTIV, P58
[4]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[5]  
DZIEGIEC J, 1971, ACTA CHIM SOC SCI LO, V16, P69
[6]  
EVANS A, 1987, POTENTIOMETRY ION SE, P121
[7]  
FRANCO DW, 1977, ANAL LETT, V10, P243
[8]   DISTRIBUTION OF SALTS OF LARGE CATIONS BETWEEN WATER AND ORGANIC-SOLVENTS .2. FACTORS AFFECTING MAGNITUDE OF DISTRIBUTION RATIO [J].
GIBSON, NA ;
WEATHERB.DC .
ANALYTICA CHIMICA ACTA, 1972, 58 (01) :159-&
[9]  
HASSAN SSM, 1991, J ASSOC OFF ANA CHEM, V74, P900
[10]   POTENTIOMETRIC GAS SENSOR FOR THE SELECTIVE DETERMINATION OF AZIDES [J].
HASSAN, SSM ;
AHMED, MA ;
MARZOUK, SAM ;
ELNEMMA, EM .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1547-1552