EFFECT OF TISSUE INHOMOGENEITY ON DOSE DISTRIBUTION OF POINT SOURCES OF LOW-ENERGY ELECTRONS

被引:16
作者
KWOK, CS [1 ]
BIALOBZYSKI, PJ [1 ]
YU, SK [1 ]
PRESTWICH, WV [1 ]
机构
[1] MCMASTER UNIV,HAMILTON L8N 3Z5,ONTARIO,CANADA
关键词
D O I
10.1118/1.596554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perturbation in dose distributions of point sources of low-energy electrons at planar interfaces of cortical bone (CB) and red marrow (RM) was investigated experimentally and by Monte Carlo codes EGS and the tiger series. Ultrathin LiF thermoluminescent dosimeters were used to measure the dose distributions of point sources of 204T1 and 147Pm im RM. When the point sources were at 12 mg/cm2from a planar interface of CB and RM equivalent plastics, dose enhancement ratios in RM averaged over the region 0–12 mg/cm2 from the interface were measured to be 1.08 ± 0.03 (SE) and 1.03 ± 0.03 (SE) for 204T1 and 147Pm, respectively. The Monte Carlo codes predicted 1.05 + 0.02 and 1.01 ±0.02 for the two nuclides, respectively. However, egs gave consistently 3% higher dose in the dose scoring region than the tiger series when point sources of monoenergetic electrons up to 0.75 MeV energy were considered in the homogeneous RM situation or in the CB and RM heterogeneous situation. By means of the tiger series, it was demonstrated that aluminum, which is normally assumed to be equivalent to CB in radiation dosimetry, leads to an overestimation of backscattering of low-energy electrons in soft tissue at a CB-soft-tissue interface by as much as a factor of 2. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 13 条
[1]   ELECTRON BACKSCATTERING [J].
BAILY, NA .
MEDICAL PHYSICS, 1980, 7 (05) :514-519
[2]   VARIATION OF BETA DOSE ATTENUATION IN DIFFERENT MEDIA [J].
CROSS, WG .
PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (04) :611-&
[3]  
ECKERMAN KF, 1985, DE86010102 US DEP EN, P514
[4]   ELECTRON DEPTH - DOSE DISTRIBUTION MEASUREMENTS IN 2-LAYER SLAB ABSORBERS [J].
EISEN, H ;
ROSENSTEIN, M ;
SILVERMAN, J .
RADIATION RESEARCH, 1972, 52 (03) :429-447
[5]  
FORD RL, 1978, SLAC210 REP
[6]   EFFECT OF TISSUE INHOMOGENEITY ON BETA DOSE DISTRIBUTION OF P-32 [J].
KWOK, CS ;
IRFAN, M ;
WOO, MK ;
PRESTWICH, WV .
MEDICAL PHYSICS, 1987, 14 (01) :98-104
[7]   PENETRATION OF BACKSCATTERED ELECTRONS IN POLYSTYRENE FOR ENERGIES BETWEEN 1 AND 25 MEV [J].
LAMBERT, GD ;
KLEVENHAGEN, SC .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (05) :721-725
[8]  
PRESTWICH WV, 1989, J NUCL MED, V30, P1036
[10]   VARIATION OF BETA-RAY BACKSCATTERING WITH TARGET THICKNESS [J].
SHARMA, KK ;