PHARMACEUTICAL CALORIMETRY - A SELECTIVE REVIEW

被引:42
作者
BUCKTON, G [1 ]
RUSSELL, SJ [1 ]
BEEZER, AE [1 ]
机构
[1] UNIV KENT,CHEM LAB,CANTERBURY CT2 7NH,KENT,ENGLAND
关键词
D O I
10.1016/0040-6031(91)80184-K
中图分类号
O414.1 [热力学];
学科分类号
摘要
Calorimetric investigations of systems of pharmaceutical interest are selectively reviewed. Attention is drawn to the need for more systematic and quantitative investigations of bioactivity, especially of synergic and antagonistic drug combinations. Formulation affects biological response (BR) and hence attention is given in this review to some of the factors that may be of biopharmaceutical importance.
引用
收藏
页码:195 / 214
页数:20
相关论文
共 65 条
[1]  
ANGBERG M, 1988, ACTA PHARM SUEC, V25, P307
[2]   OUTLINE OF DETAILS FOR MICROBIOLOGICAL ASSAYS OF ANTIBIOTICS - SECOND REVISION [J].
ARRET, B ;
JOHNSON, DP ;
KIRSHBAUM, A .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1971, 60 (11) :1689-+
[3]   INVITRO DISSOLUTION TESTING OF ORAL CONTROLLED RELEASE PREPARATIONS IN THE PRESENCE OF ARTIFICIAL FOODSTUFFS .1. EXPLORATION OF ALTERNATIVE METHODOLOGY - MICROCALORIMETRY [J].
ASHBY, LJ ;
BEEZER, AE ;
BUCKTON, G .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1989, 51 (03) :245-251
[4]   QUANTITATIVE STRUCTURE-ACTIVITY-RELATIONSHIPS - A GROUP ADDITIVITY SCHEME FOR BIOLOGICAL RESPONSE OF ESCHERICHIA-COLI TO THE ACTION OF ORTHO-ALKOXYPHENOL, META-ALKOXYPHENOL AND PARA-ALKOXYPHENOL [J].
BEEZER, AE ;
GOOCH, CA ;
HUNTER, WH ;
LIMA, MCP ;
SMITH, BV .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1987, 38 (1-3) :251-254
[5]   MICROCALORIMETRIC MEASUREMENT OF THE ENTHALPIES OF TRANSFER OF A SERIES OF ORTHO-ALKOXYPHENOLS AND PARA-ALKOXYPHENOLS FROM WATER TO OCTAN-1-OL AND FROM ISOTONIC SOLUTION TO ESCHERICHIA-COLI-CELLS [J].
BEEZER, AE ;
LIMA, MCP ;
FOX, GG ;
ARRIAGA, P ;
HUNTER, WH ;
SMITH, BV .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1987, 83 :2705-2707
[6]   COMBINED MICRO-ASSAY AND DETERMINATION OF BIOACTIVITY OF N-ACETYLNYSTATIN BY FLOW MICRO-CALORIMETRY [J].
BEEZER, AE ;
CHOWDHRY, BZ .
TALANTA, 1980, 27 (01) :1-5
[7]   BIOASSAY OF NYSTATIN BULK MATERIAL BY FLOW MICROCALORIMETRY [J].
BEEZER, AE ;
NEWELL, RD ;
TYRRELL, HJV .
ANALYTICAL CHEMISTRY, 1977, 49 (01) :34-37
[8]   MICROCALORIMETRIC MEASUREMENT OF THE ENTHALPIES OF TRANSFER OF A SERIES OF META-ALKOXYPHENOLS FROM ISOTONIC AQUEOUS-SOLUTION TO ESCHERICHIA-COLI-CELLS [J].
BEEZER, AE ;
VOLPE, PLO ;
MILES, RJ ;
HUNTER, WH .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :2929-2932
[9]   FLOW MICRO-CALORIMETRIC BIOASSAY OF POLYENE ANTIBIOTICS - INTERACTION WITH GROWING SACCHAROMYCES-CEREVISIAE [J].
BEEZER, AE ;
CHOWDHRY, BZ .
EXPERIENTIA, 1981, 37 (08) :828-831
[10]   BIOASSAY OF ANTIFUNGAL ANTIBIOTICS BY FLOW MICROCALORIMETRY [J].
BEEZER, AE ;
CHOWDHRY, BZ ;
NEWELL, RD ;
TYRRELL, HJV .
ANALYTICAL CHEMISTRY, 1977, 49 (12) :1781-1784