TECHNETIUM 99M SESTAMIBI IN THE ASSESSMENT OF CHRONIC CORONARY-ARTERY DISEASE

被引:111
作者
BERMAN, DS
KIAT, H
VANTRAIN, K
GARCIA, E
FRIEDMAN, J
MADDAHI, J
机构
[1] EMORY UNIV,SCH MED,DEPT NUCL MED,ATLANTA,GA 30322
[2] UNIV CALIF LOS ANGELES,SCH MED,DEPT MED,LOS ANGELES,CA 90024
[3] CEDARS SINAI MED CTR,DEPT MED,DIV CARDIOL,LOS ANGELES,CA 90048
[4] UNIV CALIF LOS ANGELES,SCH MED,DEPT RADIOL,LOS ANGELES,CA 90024
关键词
D O I
10.1016/S0001-2998(05)80040-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Extensive work has already been performed with regard to both planar and single photon emission computed (SPECT) technetium 99m sestamibi studies. Before widespread application of optimized acquisition and processing methods, clinical results between 99mTc sestamibi and thallium 201 were remarkably similar. It is anticipated that as techniques for 99mTc sestamibi planar and SPECT imaging become optimized, improvements in sensitivity and specificity for detection of coronary artery disease, over those observed with 201Tl, might be forthcoming. This expectation is based on the improved image quality inherent in the use of the 99mTc agent with its higher count rate and higher energy. This improvement in image quality may be a principal reason for laboratories to switch from 201Tl to 99mTc sestamibi imaging. It is anticipated that, with improved imaging characteristics, it will be easier for the average community hospital to obtain higher quality planar or SPECT imaging using 99mTc sestamibi rather than 201Tl. In addition to improved image quality, the characteristics of 99mTc sestamibi allow gated planar or SPECT perfusion images to be obtained. It has been suggested that stress-gated SPECT sestamibi studies may provide all the information contained in a stress-rest nongated 99mTc sestamibi study, thereby potentially increasing patient throughput, a major concern with SPECT. Throughput can also be increased by using dual-isotope approaches with rest 201Tl and stress technetium sestamibi acquisitions, employing either separate or simultaneous imaging with which the entire study can be accomplished in less than 2 hours. With simultaneous dual-isotope acquisition, camera time can be reduced by 50%. Finally, 99mTc sestamibi offers the advantage of the ability to perform first-pass exercise ventricular function and SPECT myocardial perfusion studies with a single injection of tracer. Regarding the assessment of myocardial viability, results to date suggest a very high degree of concordance between 201Tl and 99mTc sestamibi studies using either planar or SPECT acquisition techniques. Correlative rest studies with both tracers will be of particular interest, as will preoperative and postoperative and position emission tomography correlation studies. © 1991 W.B. Saunders Company. All rights reserved.
引用
收藏
页码:190 / 212
页数:23
相关论文
共 53 条
[1]  
BAILLET GY, 1989, J NUCL MED, V30, P38
[2]   IDENTIFICATION OF VIABLE MYOCARDIUM IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE AND LEFT-VENTRICULAR DYSFUNCTION - COMPARISON OF THALLIUM SCINTIGRAPHY WITH REINJECTION AND PET IMAGING WITH F-18 FLUORODEOXYGLUCOSE [J].
BONOW, RO ;
DILSIZIAN, V ;
CUOCOLO, A ;
BACHARACH, SL .
CIRCULATION, 1991, 83 (01) :26-37
[3]   COMBINED EXERCISE RADIONUCLIDE ANGIOCARDIOGRAPHY AND SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY PERFUSION STUDIES FOR ASSESSMENT OF CORONARY-ARTERY DISEASE [J].
BORGESNETO, S ;
COLEMAN, RE ;
POTTS, JM ;
JONES, RH .
SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (03) :223-229
[4]   TC-99M-METHOXY-ISOBUTYL-ISONITRILE SPECT TO EVALUATE A PERFUSION INDEX FROM REGIONAL MYOCARDIAL UPTAKE AFTER EXERCISE AND AT REST - RESULTS OF A 4 HOUR PROTOCOL IN PATIENTS WITH CORONARY HEART-DISEASE AND IN CONTROLS [J].
BUELL, U ;
DUPONT, F ;
UEBIS, R ;
KAISER, HJ ;
KLEINHANS, E ;
RESKE, SN ;
HANRATH, P .
NUCLEAR MEDICINE COMMUNICATIONS, 1990, 11 (02) :77-94
[5]   RELATIONS OF THE MYOCARDIAL IMAGING AGENTS TC-99M-MIBI AND TL-201 TO MYOCARDIAL BLOOD-FLOW IN A CANINE MODEL OF MYOCARDIAL ISCHEMIC INSULT [J].
CANBY, RC ;
SILBER, S ;
POHOST, GM .
CIRCULATION, 1990, 81 (01) :289-296
[7]  
CULLOM S J, 1991, Journal of Nuclear Medicine, V32, P1067
[8]   ENHANCED DETECTION OF ISCHEMIC BUT VIABLE MYOCARDIUM BY THE REINJECTION OF THALLIUM AFTER STRESS REDISTRIBUTION IMAGING [J].
DILSIZIAN, V ;
ROCCO, TP ;
FREEDMAN, NMT ;
LEON, MB ;
BONOW, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (03) :141-146
[9]  
ELLIOT AT, 1988, NUCL MED COMMUN, V9, P154
[10]   MYOCARDIAL CLEARANCE OF TC-99M HEXAKIS-2-METHOXY-2-METHYLPROPYL ISONITRILE (MIBI) IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
FRANCESCHI, M ;
GUIMOND, J ;
ZIMMERMAN, RE ;
PICARD, MV ;
ENGLISH, RJ ;
CARVALHO, PA ;
TUMEH, SS ;
HOLMAN, BL .
CLINICAL NUCLEAR MEDICINE, 1990, 15 (05) :307-312