THE ELECTRICAL EFFECT OF 2 COMMONLY USED CLINICAL STIMULATORS ON TRAUMATIC EDEMA IN RATS

被引:16
作者
COSGROVE, KA
ALON, G
BELL, SF
FISCHER, SR
FOWLER, NR
JONES, TL
MYAING, JC
CROUSE, TM
SEAMAN, LJ
机构
[1] GOOD SAMARITAN HOSP,BALTIMORE,MD 21239
[2] UNIV MARYLAND,SCH MED,DEPT PHYS THERAPY,BALTIMORE,MD 21201
[3] FRANCIS SCOTT KEY MED CTR,BALTIMORE,MD 21224
[4] MAGEE MEM REHABILITAT CTR,PHILADELPHIA,PA 19102
[5] MILLS MEM HOSP,SAN MATEO,CA 94401
[6] VALLEY PHYS THERAPY GRP,LANCASTER,CA 93534
[7] SHADY GROVE ADVENTIST HOSP,ROCKVILLE,MD 20850
[8] HOLY CROSS HOSP,SILVER SPRING,MD 20910
来源
PHYSICAL THERAPY | 1992年 / 72卷 / 03期
关键词
ANIMAL; EDEMA; ELECTROTHERAPY; ELECTRICAL STIMULATION; RATS; WOUNDS AND INJURIES;
D O I
10.1093/ptj/72.3.227
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purposes of this study were to determine the effect of electrical stimulation on traumatic rat hind-paw edema and to establish whether there would be a difference in edema reduction when two types of stimulators were used. The animals were divided into a control group (n = 15) and two experimental groups, one group receiving monophasic pulsed current (MPC group, n = 15) and the other group receiving symmetrical biphasic pulsed current (SBPC group, n = 14). The right hind-paw volume of all groups was measured prior to traumatization and at 24, 48, 72, and 96 hours posttrauma. Following the 24-, 48-, and 72-hour measurements, 1 hour of electrical stimulation was administered to the experimental groups. The control group received sham treatment. Results revealed significant edema reduction in all groups over the 96-hour period, with each group's greatest change in paw volume occurring 48 hours posttrauma. At the final paw volume measurement, there was no significant difference between the MPC and control groups or between the MPC and SBPC groups. The SBPC group, however, showed less reduction in edema than did the control group. One hour of electrical stimulation per day over 3 consecutive days failed to demonstrate significant edema reduction in either the MPC group or the SBPC group as compared with the control group. The results of this study demonstrated that the electrical stimulation characteristics and procedures currently used in the clinic do not significantly reduce extant edema caused by trauma in rat hind limbs.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 27 条
  • [1] Alon G, 1991, CLIN ELECTROTHERAPY, P35
  • [2] ALON G, 1987, HIGH VOLTAGE STIMULA, P129
  • [3] ARVIDSSON I, 1986, ORTHOPEDICS, V9, P1346
  • [4] INFLUENCE OF HIGH-VOLTAGE PULSED DIRECT-CURRENT ON EDEMA FORMATION FOLLOWING IMPACT INJURY
    BETTANY, JA
    FISH, DR
    MENDEL, FC
    [J]. PHYSICAL THERAPY, 1990, 70 (04): : 219 - 224
  • [5] BETTANY JA, 1990, ARCH PHYS MED REHAB, V71, P677
  • [6] BETTANY JA, 1990, J CLIN ELECTROPHYSIO, V2, P5
  • [7] BLACK J, 1984, ORTHOP CLIN N AM, V15, P15
  • [8] ELECTRIC-STIMULATION OF PROTEIN AND DNA-SYNTHESIS IN HUMAN-FIBROBLASTS
    BOURGUIGNON, GJ
    BOURGUIGNON, LYW
    [J]. FASEB JOURNAL, 1987, 1 (05) : 398 - 402
  • [9] Brown S, 1981, Phys Sportsmed, V9, P137, DOI 10.1080/00913847.1981.11711218
  • [10] PREVENTION OF POSTOPERATIVE LEG VEIN THROMBOSIS BY ELECTRICAL MUSCLE STIMULATION - AN EVALUATION WITH (I-125)-LABELLED FIBRINOGEN
    BROWSE, NL
    NEGUS, D
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1970, 3 (5723): : 615 - +