CRITERIA FOR THE DESIGN OF FETAL HEART-RATE ANALYSIS SYSTEMS

被引:64
作者
DAWES, GS
MOULDEN, M
REDMAN, CWG
机构
[1] Nuffield Department of Obstetrics and Gynaecology, John Radcliffe Hospital, UK- Oxford, 0X3 9DU, Headington
来源
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING | 1990年 / 25卷 / 04期
关键词
Acceleration; Deceleration; Fetal heart rate; Fetal movements; FHR variation; Growth retardation;
D O I
10.1016/0020-7101(90)90032-P
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Criteria are described for the automated analysis of fetal pulse intervals, fetal movements and of uterine contractions measured externally, antenatally and interactively on-line, for implementation on a personal computer interfaced to an appropriate fetal monitor, and tested on 10,000 records. Measurements of short and longer term fetal heart rate variation are compared; both are required to identify sinister records. Recall and display of records acquired on the same patient over several weeks has proved a useful diagnostic aid. © 1990.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 11 条
[1]   PATTERN OF THE NORMAL HUMAN-FETAL HEART-RATE [J].
DAWES, GS ;
HOUGHTON, CRS ;
REDMAN, CWG ;
VISSER, GHA .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (04) :276-284
[2]   BASELINE IN HUMAN-FETAL HEART-RATE RECORDS [J].
DAWES, GS ;
HOUGHTON, CRS ;
REDMAN, CWG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (04) :270-275
[3]   LIMITATIONS OF ANTENATAL FETAL HEART-RATE MONITORS [J].
DAWES, GS ;
MOULDEN, M ;
REDMAN, CWG .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 162 (01) :170-173
[4]   IMPROVEMENTS IN THE REGISTRATION AND ANALYSIS OF FETAL HEART-RATE RECORDS AT THE BEDSIDE [J].
DAWES, GS ;
REDMAN, CWG ;
SMITH, JH .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (04) :317-325
[5]   CHARACTERIZATION OF THE REDUCED HEART-RATE VARIATION IN GROWTH-RETARDED FETUSES [J].
HENSON, G ;
DAWES, GS ;
REDMAN, CWG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (08) :751-755
[6]   ANTENATAL FETAL HEART-RATE-VARIABILITY IN RELATION TO FETAL ACID-BASE STATUS AT CESAREAN-SECTION [J].
HENSON, GL ;
DAWES, GS ;
REDMAN, CWG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1983, 90 (06) :516-521
[7]   A COMPARISON OF 2 FETAL HEART-RATE ULTRASOUND DETECTOR SYSTEMS [J].
LAWSON, G ;
DAWES, GS ;
REDMAN, CWG .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 143 (07) :840-842
[8]   A COMPARISON OF ULTRASOUND (WITH AUTO-CORRELATION) AND DIRECT ELECTROCARDIOGRAM FETAL HEART-RATE DETECTOR SYSTEMS [J].
LAWSON, GW ;
BELCHER, R ;
DAWES, GS ;
REDMAN, CWG .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1983, 147 (06) :721-722
[9]   LOW HUMAN-FETAL HEART-RATE VARIATION IN NORMAL-PREGNANCY [J].
SMITH, JH ;
DAWES, GS ;
REDMAN, CWG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (07) :656-664
[10]   ANTENATAL FETAL HEART-RATE VARIATION IN RELATION TO THE RESPIRATORY AND METABOLIC STATUS OF THE COMPROMISED HUMAN-FETUS [J].
SMITH, JH ;
ANAND, KJS ;
COTES, PM ;
DAWES, GS ;
HARKNESS, RA ;
HOWLETT, TA ;
REES, LH ;
REDMAN, CWG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1988, 95 (10) :980-989