MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY - A COMPARISON OF [O-15]WATER TO [C-11] BUTANOL WITH DISTRIBUTED-PARAMETER AND COMPARTMENTAL-MODELS

被引:36
作者
QUARLES, RP
MINTUN, MA
LARSON, KB
MARKHAM, J
MACLEOD, AM
RAICHLE, ME
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,DIV RADIAT SCI,510 S KINGSHIGHWAY,ST LOUIS,MO 63110
[2] UNIV FLORIDA,DEPT RADIOL,GAINESVILLE,FL 32611
[3] UNIV PITTSBURGH,DIV NUCL MED,PITTSBURGH,PA 15260
[4] WASHINGTON UNIV,DEPT NEUROL & NEUROSURG,ST LOUIS,MO 63130
[5] WASHINGTON UNIV,INST BIOMED COMP,ST LOUIS,MO 63130
关键词
BLOOD FLOW TRACERS; BRAIN ACTIVATION; COMPARTMENTAL MODELS; DISPERSION AND DELAY; DISTRIBUTED-PARAMETER MODELS; POSITRON EMISSION TOMOGRAPHY; REGIONAL CEREBRAL BLOOD FLOW;
D O I
10.1038/jcbfm.1993.94
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To further our understanding of the best way to measure regional CBF with positron emission tomography (PET), we directly compared two candidate tracers ([O-15]water and [C-11]butanol, administered intravenously) and two popular implementations of the one-compartment (1C) model: the autoradiographic implementation representing a single PET measurement of tissue radioactivity over 1 min and a dynamic implementation representing a sequence of measurements of tissue radioactivity over 200 s. We also examined the feasibility of implementing a more realistic, and thus more complex, distributed-parameter (DP) model by assigning fixed values for all of its parameters other than CBF and tracer volume of distribution (Vd), a requirement imposed by the low temporal resolution and statistical quality of PET data. The studies were performed in three normal adult human subjects during paired rest and visual stimulation. In each subject seven regions of interest (ROIs) were selected, one of which was the primary visual cortex. The corresponding ROI were anatomically equivalent in the three subjects. Regional CBF, V(d), tracer arrival delay, and dispersion were estimated for the dynamic data curves. A total of 252 parameter sets were estimated. With [C-11]butanol both implementations of the 1C model provided similar results (r = 0.97). Flows estimated using the 1C models were lower (p < 0.01) with [O-15]water than with [C-11]butanol. In comparison with the 1C model, the constrained version of the DP used in these studies performed inadequately, overestimating high flow and underestimating low flow with both tracers, possibly as the result of the necessity of assigning fixed values for all of its parameters other than CBF and V(d).
引用
收藏
页码:733 / 747
页数:15
相关论文
共 53 条
[1]   STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY [J].
ALPERT, NM ;
ERIKSSON, L ;
CHANG, JY ;
BERGSTROM, M ;
LITTON, JE ;
CORREIA, JA ;
BOHM, C ;
ACKERMAN, RH ;
TAVERAS, JM .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :28-34
[2]  
Beck JV., 1977, PARAMETER ESTIMATION
[3]   MEASUREMENT OF HUMAN CEREBRAL BLOOD-FLOW WITH [O-15]BUTANOL AND POSITRON EMISSION TOMOGRAPHY [J].
BERRIDGE, MS ;
ADLER, LP ;
NELSON, AD ;
CASSIDY, EH ;
MUZIC, RF ;
BEDNARCZYK, EM ;
MIRALDI, F .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (05) :707-715
[4]  
BERRIDGE MS, 1990, J NUCL MED, V31, P1727
[5]   DIFFUSION PERMEABILITY TO WATER OF RAT BLOOD-BRAIN-BARRIER [J].
BOLWIG, TG ;
LASSEN, NA .
ACTA PHYSIOLOGICA SCANDINAVICA, 1975, 93 (03) :415-422
[6]   A COMPARISON BETWEEN REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS OBTAINED IN HUMAN-SUBJECTS USING C-11 METHYLALBUMIN MICROSPHERES, THE C15O2 STEADY-STATE METHOD, AND POSITRON EMISSION TOMOGRAPHY [J].
BROOKS, DJ ;
FRACKOWIAK, RSJ ;
LAMMERTSMA, AA ;
HEROLD, S ;
LEENDERS, KL ;
SELWYN, AP ;
TURTON, DR ;
BRADY, F ;
JONES, T .
ACTA NEUROLOGICA SCANDINAVICA, 1986, 73 (04) :415-422
[7]   WEIGHTED INTEGRATION METHOD FOR LOCAL CEREBRAL BLOOD-FLOW MEASUREMENTS WITH POSITRON EMISSION TOMOGRAPHY [J].
CARSON, RE ;
HUANG, SC ;
GREEN, MV .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (02) :245-258
[8]   EVIDENCE OF LIMITATIONS OF WATER AS A FREELY DIFFUSIBLE TRACER IN BRAIN OF RHESUS-MONKEY [J].
EICHLING, JO ;
RAICHLE, ME ;
GRUBB, RL ;
TERPOGOS.MM .
CIRCULATION RESEARCH, 1974, 35 (03) :358-364
[9]   REGIONAL CEREBRAL BLOOD-FLOW IN RAT MEASURED BY TISSUE SAMPLING TECHNIQUE - CRITICAL EVALUATION USING 4 INDICATORS C14-ANTIPYRINE, ETHANOL-C-14 WATER-H-3 AND X-133 [J].
EKLOF, B ;
LASSEN, NA ;
NILSSON, L ;
NORBERG, K ;
SIESJO, BK ;
TORLOF, P .
ACTA PHYSIOLOGICA SCANDINAVICA, 1974, 91 (01) :1-10
[10]   A STEREOTACTIC METHOD OF ANATOMICAL LOCALIZATION FOR POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
PERLMUTTER, JS ;
RAICHLE, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :141-153