摘要
We have fabricated and characterized two new cocaine-sensitive ISFET devices based on a PVC-sebacate membrane containing cocaine-reineckate or cocaine-tetraphenylborate as exchanger. Both the ISFET sensors display a linearity range for cocaine hydrochloride between about 3X10(-6) and 2X10(-2) mol l(-1) and a fast response (less than or equal to 25 s), which remain almost the same in the pH range 3-7. For the cocaine-reineckate and cocaine-tetraphenylborate ISFETs, the slope values are -53.9 and -51.3 Delta mV/Delta log c (c=mol l(-1)), and the precision of the measurements, as 'pooled SD%' is 1.1 or 3.5, respectively. Selectivity coefficient values for several possible interferences have been determined and the application of these sensors to the analysis of authentic samples containing cocaine and other substances commonly associated with it is also reported.
引用
收藏
页码:188 / 193
页数:6
相关论文
共 19 条
[1]   CHOLANIC ACIDS DETERMINED IN COMMERCIAL DRUGS BY MEANS OF A NEW ISFET DEVICE [J].
CAMPANELLA, L ;
BATTILOTTI, M ;
BORRACCINO, A ;
COLAPICCHIONI, C ;
SAMMARTINO, MP ;
TOMASSETTI, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1207-1214
[2]  
CAMPANELLA L, 1990, BIOINSTRUMENTATION R, P1369
[3]  
CAMPANELLA L, 1994, SENSOR ACTUAT B-CHEM, V18, P321
[4]  
CAMPANELLA L, 1993, INQUINAMENTO, V35, P52
[5]  
CAMPANELLA L, 1988, ANALUSIS S9, V16, P120
[6]   POTENTIOMETRIC TITRATION OF ORGANIC CATIONS WITH SODIUM TETRAPHENYLBORATE AND A LIQUID-MEMBRANE TETRAPHENYLBORATE ION-SELECTIVE ELECTRODE [J].
CHRISTOPOULOS, TK ;
DIAMANDIS, EP ;
HADJIIOANNOU, TP .
ANALYTICA CHIMICA ACTA, 1982, 143 (01) :143-151
[7]   ION-SELECTIVE ELECTRODES FOR BASIC DRUGS [J].
CUNNINGHAM, L ;
FREISER, H .
ANALYTICA CHIMICA ACTA, 1982, 139 (JUL) :97-103
[8]   A QUANTITATIVE DENSITOMETRIC DETERMINATION OF HEROIN AND COCAINE SAMPLES BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY [J].
DELLACASA, E ;
MARTONE, G .
FORENSIC SCIENCE INTERNATIONAL, 1986, 32 (02) :117-120
[9]   POTENTIOMETRIC DETERMINATION OF SOME COMMON ALKALOIDS WITH A PICRATE-SELECTIVE ELECTRODE [J].
DIAMANDIS, EP ;
HADJIIOANNOU, TP .
ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) :341-345
[10]   LIQUID AND POLY (VINYL-CHLORIDE) MATRIX MEMBRANE ELECTRODES FOR THE SELECTIVE DETERMINATION OF COCAINE IN ILLICIT POWDERS [J].
ELNEMMA, EM ;
HAMADA, MA ;
HASSAN, SSM .
TALANTA, 1992, 39 (10) :1329-1335