摘要
研究离子色谱柱后衍生紫外检测法快速测定面制品中溴酸盐含量。采用IonPac AS19分析柱(250 mm×4 mm),IonPac AG19保护柱(50 mm×4 mm),KOH梯度淋洗,柱温30℃。以0.26 mol/L KI为衍生试剂,2.0mmol/L(NH4)6Mo7O24.4H2O为催化剂,检测波长352 nm。样品用纯水萃取,经高速离心20 min(转速10 000 r/min),过C18预处理小柱,用0.45μm膜过滤后直接进样。试验结果表明,在0.01~1.0 mg/L范围,方法相关系数为0.9996,加标平均回收率85.0%~101.4%,检出限0.004 mg/L。该方法操作简单方便,灵敏选择性高,适用于常规样品分析。
引用
收藏
页码:221 / 225
页数:5
相关论文
共 8 条
[1]
Determination of inorganic oxyhalide disinfection by-products in bottled water by EPA Method 326.0 for trace bromate analysis.[J].Vasileios M. Matsis;Evagoras C. Nikolaou.Desalination.2008, 1
[2]
Liquid-phase microextraction–gas chromatography–mass spectrometry for the determination of bromate; iodate; bromide and iodide in high-chloride matrix.[J].Kishan Reddy-Noone;Archana Jain;Krishna K. Verma.Journal of Chromatography A.2007, 2
[3]
Determination of bromate ion in drinking water by capillary zone electrophoresis with direct photometric detection.[J].Toshio Takayanagi;Makoto Ishida;Julius Mbuna;Rim Driouich;Shoji Motomizu.Journal of Chromatography A.2006, 1
[4]
Ion chromatographic determination of trace iodate, chlorite, chlorate, bromide, bromate and nitrite in drinking water using suppressed conductivity detection and visible detection [J].
Zhu, Binghui ;
Zhong, Zhixiong ;
Yao, Jing .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1118 (01) :106-110
[5]
Simultaneous determination of trace level bromate and chlorinated haloacetic acids in bottled drinking water by ion chromatography [J].
Liu, YJ ;
Mou, SF .
MICROCHEMICAL JOURNAL, 2003, 75 (02) :79-86
[6]
Determination of trace level bromate and perchlorate in drinking water by ion chromatography with an evaporative preconcentration technique.[J].Yongjian Liu;Shifen Mou;Shawn Heberling.Journal of Chromatography A.2002, 1
[7]
Ion chromatographic determination of bromate in drinking water by post-column reaction with fuchsin.[J].M Achilli;L Romele.Journal of Chromatography A.1999, 1
[8]
Determination of bromate at parts-per-trillion levels by gas chromatography–mass spectrometry with negative chemical ionization.[J].Matthew L. Magnuson.Analytica Chimica Acta.1998, 1