目的 评估内嵌Marsh等报道的药代学参数的TCI系统的准确性。方法22例ASAⅠ~Ⅱ级择期手术患者,<65岁(Y组)和>65岁(E组)各11例,异丙酚靶浓度从2μg/ml开始以1μg/ml递增直至意识消失,分析血浆浓度。计算每个样本的百分比预测误差(%PE)、稳定误差(%CE)和组间个体内中位数预测误差(MDPE)、中位数绝对误差(MDAPE)、中位数稳定误差(MDCE)、中位数绝对稳定误差(MDACE)。结果 升高靶浓度时系统产生明显的超射。E组异丙酚血浆浓度的PE和绝对值PE分别是63.3%和66.2%,Y组则分别是62.1%和62.7%。E组CE和绝对值CE分别是-0.3%和12.7%,Y组则分别是0.6%和13.5%,组间无差异(P>0.05)。E组和Y组中位数MDPE(=中位数MDAPE)分别为78.1%和66.1%,MDCE分别是-0.2%和0.8%,MDACE分别是12.5%和13.5%。实测浓度和预测浓度呈显著直线相关(P<0.01)。结论Marsh参数用于国人靶控输注,实测浓度和预测浓度的差异性较大,但系统能够维持稳定的血浆浓度。
引用
收藏
页码:20 / 23
页数:4
相关论文
共 11 条
[1]  
Testing computer-controlled infusion pumps by simulation. Shafer SL,Siegel LC,Cooke James,et al. Anesthesiology . 1988
[2]  
Reduction by fentanyl of Cp50 Values of propofol and hemodynamic responses to various noxious stimuli. Kazama T,Ikeda K,Morita K. Anesthesiology . 1997
[3]  
Population pharmac-okinetics of midazolam administration by target controlled infusion for sedation following coronary artery bypass grafting. Zomorodi K,Donner A,Somma J,et al. Anesthesiology . 1998
[4]  
Computer-assisted continuous infusions of fentanyl during cardiac anesthesia: comparison with a manual method. Alvis JM,Reves JG,Govier AV,et al. Anesthesiology . 1985
[5]  
Population pharmacokinetic of propofol. Schuttler J,Ihmsen H. Anesthesiology . 2000
[6]  
Prospective evaluation of pharmacokinetic model-controlled infusion of propofol in adult patients. Short TG,Lim TA,Tam YH. British Journal of Anaesthesia . 1996
[7]  
Pharmacokinetic model driven infusion of propofol in children. Marsh B,White M,Morton N,et al. British Journal of Anaesthesia . 1991
[8]  
Patient-maintained propofol sedation: assessment of a target-controlled infusion system. Irwin MG,Thompson N,Kenny NC. Anaesthesia . 1997
[9]  
Pharmacokinetic model selection for target controlled infusions of propofol, assessment of three parameter sets. CotzeeJF,Glen JB,Wium CA,et al. Anesthesiology . 1995
[10]  
Performance of computer-assisted continuous infusion at low concentration of intravenous sedatives. Veselis PA,Glass P,Danistrian A,et al. Anesthesia and Analgesia . 1997