60Co单板源堆码辐照剂量不均匀度分析

被引:3
作者
郭平稳
李松兰
张磊
杨利军
尹艳艳
机构
[1] 西北核技术研究所
[2] 西北核技术研究所 西安
[3] 西安
关键词
吸收剂量不均匀度; 钴源辐照;
D O I
暂无
中图分类号
TQ460 [一般性问题];
学科分类号
1007 ;
摘要
To verify quality of irradiated products by a 3.9PBq single plate (1m×1m) source, Ag2Cr2O7 dosimeters were used for measuring extreme doses in three kinds of Chinese medicine in a actual irradiation area of 1.4m×1.4m facing the source. The product cartons were piled on the irradiation area, and their positions were exchanged to improve dosimetry uniformity of the products. The dosimeters for monitoring the minimum dose were placed in center of the cartons. The minimum doses of the three kinds of Chinese medicine products were 2.98, 1.03 and 1.37kGy respectively, and the maximum doses were 4.61, 2.00 and 2.24kGy, respectively. The dosimetry uni- formities were 1.55, 1.94 and 1.64, respectively, which are within the quality control requirement of U≤2.
引用
收藏
页码:123 / 123
页数:1
相关论文
共 1 条
[1]  
辐射加工技术及其应用.[M].赵文彦;潘秀苗主编;.兵器工业出版社.2003,