雷电保护装置的有效性研究(英文)

被引:2
作者
S.Grzybowski
T.Disyadej
S.Mallick
机构
[1] High Voltage Laboratory
[2] Department of Electrical and Computer Engineering
[3] Mississippi State University
关键词
air terminals; critical flashover voltage; dissipator devices; emission current; Franklin Rod; lightning; lightning leader; lightning protection; space charge;
D O I
10.13336/j.1003-6520.hve.2008.12.018
中图分类号
TM862 [过电压保护装置];
学科分类号
080803 ;
摘要
In addition to the conventional Franklin Rod,many non-conventional air terminals are being used as lightning protection devices.As cited in previous works,these non-conventional devices emit space charge in the vicinity of the terminals during the process of lightning stroke.A number of factors affect the performance of these lightning protection devices,among them are geometry and dimension of the devices,location of the device above the ground,height of the cloud above the ground,and polarity of the lightning stroke.The performance of these lightning protection devices has been a topic of discussion by researchers for many years.Some studies focused on the magnitude of emission current from these devices as a criterion to evaluate their performances.The critical flashover voltage(CFO)between the devices and a metal screen simulating cloud can also be used as another criterion to evaluate the performance of the devices.Laboratory measurements were conducted in controlled conditions on different types of lightning protection devices to compare their performance.Four different types of devices were used in the present study:Franklin Rod,TerraStat models TS 100,TS 400,and Spline Ball Ionizer.The study focused on the CFO voltage of the air gap between devices and the metal screen.The CFO voltage was evaluated using standard switching and lightning impulses.The measurements were recorded for positive as well as negative polarity.The air gap between the devices and metal screen was selected at 2 m and 3 m.The results obtained provide a better understanding of the electrical performance of lightning protection devices.
引用
收藏
页码:2517 / 2522
页数:6
相关论文
共 10 条
[1]  
Determination of the inception electric field of the lightning upwardleader. Berger G. Proc.of8thInternational Sympo-siumof High Voltage Engineering(ISH’93) . 1993
[2]  
Lightning rod improve-ment studies. Moore C B,Rison W,Mathis J,et al. Journal of Applied Meteorology . 2000
[3]  
A critical review of nonconventional approaches tolightning protection. Uman M A,Rakov V A. Bulletin of American Me-teorological Society . 2002
[4]  
Lightning Protection Systems: Advantages and Disadvantages. DONALD W ZIPSE. 《IEEE Transaction on Industry Applications》 . 1994
[5]  
Effectiveness of light-ning protection devices. Grzybowski S,Disyadej T,Mallick S. Proc.of2008International Con-ference on High Voltage Engineering and Application(ICHVE2008) . 2008
[6]  
Experimental study on lightning protection performance of air terminals. Lee J B,Myung S H,Cho Y G,et al. Proc.Power Con2002 . 2002
[7]  
DC dissipation current fromelements used for lightning protection on115kV transmissionlines. Grzybowski S,Libby A L,Jenkins E B,et al. Proc.IEEE SoutheastCon’91Confer-ence . 1991
[8]  
Experimental study of emission current fromlightning protection devices under rain and wind conditions. Grzybowski S,Taylor C D,Bean C,et al. Proc.IX Symposium on Lightning Protection . 2007
[9]  
Emis-sion current fromstatic dissipator devices at switching impulses. Grzybowski S,Taylor C D,Rodriguez-Medina B,et al. Proc.VIII International Symposiumon Lightning Protec-tion . 2005
[10]  
Lightning per-formance tests on115kVtransmission line models with spline ball ionizers. Grzybowski S,Molen G M,SathishramS,et al. IEEE Proceedings of Southeastcon’94 . 1994