Use of fluorescent europium chelates as labels for detection of microcystin-LR in Taihu Lake, China

被引:5
作者
钮伟民 [1 ]
何恩奇 [1 ]
吴庆刚 [1 ]
周伟杰 [1 ]
张艺 [2 ]
黄飚 [2 ]
赵晓联 [3 ]
机构
[1] Laboratory Department of Municipal Center for Disease Control and Prevention
[2] Key Laboratory of Nuclear Medicine, Department of Biotechnology, Jiangsu Institute of Nuclear Medicine
[3] Jiangsu Suwei Microbiology Research Co, Ltd
关键词
microcystin; time-resolved fluoroimmunoassay (TRFIA); water; dynamic detection; dead algae; rare earths;
D O I
暂无
中图分类号
X832 [水质监测];
学科分类号
0804 ; 082803 ;
摘要
A method using the time-resolved fluorescence technology to establish a highly sensitive microcystin-LR (MC-LR) indirect competitive immunoassay was proposed in this work. This method was used to monitor the MC-LR level in source water and treated drinking water from Taihu Lake. Algae in the water samples were removed by centrifugation, and the MC-LR level was quantified using this method. Testing results showed that the sensitivity of this method was 0.01 μg/L, and the dynamic measuring range was from 0.05 to 2 μg/L. The average recovery was 115%, and the variation (CV) within and between different batches were 7.3% and 9.7%, respectively. Testing results also indicated that this time-resolved fluoroimmunoassay was sensitive and accurate in measuring MC-LR level, especially for quantitative analysis MC-LR level in bulk water.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 14 条
[1]  
Effect of gadolinium incorporation on optical characteristics of YNbO4:Eu3+ phosphors for lamp applications[J]. Sung Hwan Choi,G. Anoop,Dong Wook Suh,Kyung Pil Kim,Hyun Ju Lee,Jae Soo Yoo. Journal of Rare Earths. 2012(03)
[2]  
Synthesis of novel europium complexes and their photoluminescence properties[J]. 史林芳,李艳伟,曹华茹,关莹,马永纯. Journal of Rare Earths. 2012(01)
[3]  
Fabrication and characterization of YVO4:Eu3+ nanomaterials by the microwave technique[J]. Tran Thu Huong,Vu Duc Tu,Tran Kim Anh,Le Thi Vinh,Le Quoc Minh. Journal of Rare Earths. 2011(12)
[4]   ELISA法与HPLC法检测太湖水中藻毒素的比较研究 [J].
蔡正森 ;
王海勇 ;
孙蔚榕 ;
李晖 ;
赵晓联 .
中国卫生检验杂志, 2006, (08) :925-927
[5]   Stimulation effect of microcystin-LR on matrix metalloproteinase-2/-9 expression in mouse liver [J].
Zhang, Xu-Xiang ;
Zhang, Zongyao ;
Fu, Ziyi ;
Wang, Ting ;
Qin, Wendi ;
Xu, Lizhi ;
Cheng, Shupei ;
Yang, Liuyan .
TOXICOLOGY LETTERS, 2010, 199 (03) :377-382
[6]  
Determination of microcystin-LR and its metabolites in snail ( Bellamya aeruginosa ), shrimp ( Macrobrachium nipponensis ) and silver carp ( Hypophthalmichthys molitrix ) from Lake Taihu, China[J] . Dawen Zhang,Ping Xie,Jun Chen,Ming Dai,Tong Qiu,Yaqin Liu,Gaodao Liang. Chemosphere . 2009 (7)
[7]   Dual-label time-resolved fluoroimmunoassay for simultaneous detection of aflatoxin B1 and ochratoxin A [J].
Huang, Biao ;
Xiao, Hualong ;
Zhang, Jue ;
Zhang, Lianfen ;
Yang, Hailin ;
Zhang, Yi ;
Jin, Jian .
ARCHIVES OF TOXICOLOGY, 2009, 83 (06) :619-624
[8]   LC/MS/MS structure elucidation of reaction intermediates formed during the TiO2 photocatalysis of microcystin-LR [J].
Antoniou, Maria G. ;
Shoemaker, Jody A. ;
de la Cruz, Armah A. ;
Dionysiou, Dionysios D. .
TOXICON, 2008, 51 (06) :1103-1118
[9]   Determination of ochratoxin A by polyclonal antibodies based sensitive time-resolved fluoroimmunoassay [J].
Huang, Biao ;
Tao, Wenyi ;
Shi, Jin ;
Tang, Luhong ;
Jin, Jian .
ARCHIVES OF TOXICOLOGY, 2006, 80 (08) :481-485
[10]  
A time-resolved fluoroimmunometric assay for the detection of microcystins, cyanobacterial peptide hepatotoxins[J] . P. Mehto,M. Ankelo,A. Hinkkanen,A. Mikhailov,J.E. Eriksson,L. Spoof,J. Meriluoto. Toxicon . 2001 (6)