HPLC/MS测定人血浆中盐酸班布特罗及其代谢物特布他林的浓度

被引:6
作者
刘蕾
李可欣
史爱欣
殷琦
赫广威
孙春华
不详
机构
[1] 卫生部北京医院临床药理基地!北京
关键词
班布特罗; 特布他林; 高效液相-质谱联用;
D O I
10.16155/j.0254-1793.2001.05.004
中图分类号
R969 [临床药理学];
学科分类号
100602 ; 100706 ;
摘要
目的 :用高效液相 /质谱联用法测定人血浆中盐酸班布特罗及其代谢物特布他林的浓度。方法 :液相 :采用SupelcodiscoveryC18色谱柱 (5 μm ,2 5 0mm× 4 6mm) ;柱温 40℃ ;流动相为甲醇 -醋酸铵溶液 (0 0 0 7mol·L-1) (2 0∶80 ) (并用冰醋酸调 pH =4 8) ,流速 0 6mL·min-1,进样量 6 0 μL ;质谱 :大气压化学电离源 (APCI) ,选择性监测 (SIR)质荷比 (m/z)分别为 2 2 6 (特布他林 ) ,2 6 0 (内标 ) ,36 8(班布特罗 )带正电荷的分子离子峰定量。样品用固相萃取小柱提取处理。结果 :班布特罗线性范围 0 12 5~ 16 μg·L-1,最低检测浓度为 0 0 5 μg·L-1。特布他林线性范围 0 312 5~ 40 μg·L-1,最低检测浓度为 0 0 5 μg·L-1。班布特罗和特布他林的萃取回收率均在 90 %以上 ,日内、日间的RSD皆小于 15 %。结论 :适用于临床上测定血浆中盐酸班布特罗及其代谢物特布他林的浓度及药动学的研究
引用
收藏
页码:316 / 319
页数:4
相关论文
共 9 条
[1]  
McCarthy PT,Atwal S,Sykes AP,et al.Measurement of terbutaline and salbutamol in plasma by high performance liquid chromatography with fluorescence detection. Biomedical Chromatography . 1993
[2]  
Lindberg C,Jonsson S,Paulson J,et al.Determination of bambuterol, a prodrug of terbutaline, in plasma and urine by gas chromatography/mass spectrometry. Biomedical and Environmental Mass Spectrometry . 1990
[3]  
Nyberg L,Rosenborg J,Weibull E,et al.Pharmacokinetics of bambuterol in healthy subjects. British Journal of Clinical Pharmacology . 1998
[4]  
Palmasdottir S,Mathiasson L,Jonson JA,et al.Determination of a basic drug, bambuterol, in human plasma by capillary electrophoresis using double stacking for large volume injection and supported liquid membranes for sample pretreatment. Journal of Chromatography B . 1997
[5]  
Wannerberg O,Persson B.Liquid chromatography method for the determination of bambuterol hydrochloride and related compounds. Journal of Chromatography . 1988
[6]  
Sagar KA,Kelly MT,Smyth MR.Simultaneous determination of salbutamol and terbutaline at overdose levels in human plasma by high performance liquid chromatography with electrochemical detection. Biomedical Chromatography . 1993
[7]  
Jacobson GA,Peterson GM.High - performance liquid chromatography assay for the simultaneous determination of ipratropium bromide, fenoterol, salbutamol and terbutaline in nebulizer solution. Journal of Pharmaceutical and Biomedical Analysis . 1994
[8]  
Sagar KA,Kelly MT,Smyth MR.Analysis of terbutaline in human plasma by high - performance liquid chromatography with electrochemical detection using a micro-electrochemical flow cell. Journal of Chromatography . 1992
[9]  
Biancotto G,Angeletti R,Piro RD,et al.Related articles ion trap high-performance liquid chromatography/multiple Mass spectrometry in the determination of beta-agonists in bovine urines. Journal of Mass Spectrometry . 1997