股骨生物力学有限元分析研究进展

被引:14
作者
张思能 [1 ]
黄潮桐 [2 ]
陈隆福 [2 ]
张美超 [3 ]
机构
[1] 广东医学院
[2] 广东医学院附属厚街医院
[3] 南方医科大学临床解剖研究所
关键词
股骨; 生物力学; 有限元分析; 模型; 应力,物理; 股骨骨折; 骨折固定术,内;
D O I
暂无
中图分类号
R318.01 [生物力学];
学科分类号
100103 [病原生物学];
摘要
股骨生物力学有限元分析是目前数字骨科领域的一个研究热点。该文介绍股骨有限元模型的建立及应力分析,阐述股骨损伤机制的有限元研究结果,综述股骨生物力学有限元分析技术在手术方案指导、风险预测和预后评估以及医疗器械设计、优化和改良等方面的临床应用价值。
引用
收藏
页码:368 / 373
页数:6
相关论文
共 42 条
[1]
Experimental Validation Of Finite Element Model For Proximal Composite Femur Using Optical Measurements.[J].Lorenzo Grassi;Sami P. V??n?nen;Saber Amin Yavari;Harrie Weinans;Jukka S. Jurvelin;Amir A. Zadpoor;Hanna Isaksson.Journal of the Mechanical Behavior of Biomedical Materials.2013,
[2]
A femoral model with all relevant muscles and hip capsule ligaments [J].
Helwig, P. ;
Hindenlang, U. ;
Hirschmueller, A. ;
Konstantinidis, L. ;
Suedkamp, N. ;
Schneider, R. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (06) :669-677
[3]
Biomechanical model of a high risk impending pathologic fracture of the femur: Lesion creation based on clinically implemented scoring systems [J].
Alexander, Gerald E., III ;
Gutierrez, Sergio ;
Nayak, Aniruddh ;
Palumbo, Brian T. ;
Cheong, David ;
Letson, G. Douglas ;
Santoni, Brandon G. .
CLINICAL BIOMECHANICS, 2013, 28 (04) :408-414
[4]
Estimation of 3D shape, internal density and mechanics of proximal femur by combining bone mineral density images with shape and density templates [J].
Vaananen, Sami P. ;
Jurvelin, Jukka S. ;
Isaksson, Hanna .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2012, 11 (06) :791-800
[5]
Finite element prediction of proximal femur fracture pattern based on orthotropic behaviour law coupled to quasi-brittle damage.[J].Ridha Hambli;Awad Bettamer;Samir Allaoui.Medical Engineering and Physics.2011, 2
[6]
Comparative study of two materials for dynamic hip screw during fall and gait loading: titanium alloy and stainless steel [J].
Taheri, Nooshin S. ;
Blicblau, Aaron S. ;
Singh, Manmohan .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (06) :805-813
[7]
Patient-specific finite element analysis of the human femur-A double-blinded biomechanical validation [J].
Trabelsi, Nir ;
Yosibash, Zohar ;
Wutte, Christof ;
Augat, Peter ;
Eberle, Sebastian .
JOURNAL OF BIOMECHANICS, 2011, 44 (09) :1666-1672
[8]
Performance of modified anatomic plates is comparable to proximal femoral nail, dynamic hip screw and anatomic plates: Finite element and biomechanical testing [J].
Oken, O. Fuad ;
Soydan, Zafer ;
Yildirim, A. Ozgur ;
Gulcek, Murat ;
Ozlu, Korhan ;
Ucaner, Ahmet .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (10) :1077-1083
[9]
Multi-level patient-specific modelling of the proximal femur. A promising tool to quantify the effect of osteoporosis treatment [J].
Lenaerts, Leen ;
van Lenthe, G. Harry .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 367 (1895) :2079-2093
[10]
Effect of position and alteration in synergist muscle force contribution on hip forces when performing hip strengthening exercises.[J].Cara L. Lewis;Shirley A. Sahrmann;Daniel W. Moran.Clinical Biomechanics.2008, 1