局部放电射频信号与其视在放电量的关联分析(英文)

被引:7
作者
唐炬 [1 ]
谢彦斌 [1 ]
张晓星 [1 ]
周谦 [2 ]
机构
[1] College of Electrical Engineering,ChongQing University
[2] Chongqing Jiangbei Power Supply Bureau,Chongqing Power Corporation,State Power
关键词
radio frequency; partial discharge; discharge quantity; pulse current method; energy; linear regression curve;
D O I
暂无
中图分类号
TM83 [高电压试验设备及测量技术];
学科分类号
摘要
Radio frequency(RF) measurement has become a hot issue for partial discharge detection.However,its application is hampered by the difficulty to establish a relationship between the RF measurements data and apparent discharge quantity.In this paper,on the basis of an experimental model of metal protrusion,the relationship between the results of RF measurement and pulse current method(IEC 60270) was investigated.The energy,double integration,peak voltage,peak-peak voltage and the area of RF signals were plotted versus either the apparent discharge quantity or the square of the apparent discharge quantity in order to evaluate the optimal regression curve.At the same time,the impact of voltage and the distance between protrusion and plate were also investigated.The results indicate that the optimal match to a linear regression curve can be gained by plotting the RF signal energy versus the square of the apparent discharge quantity.The variation of voltage has no significant impact on the regression curve;that is,data from different voltages match one line.However,when the distance between protrusion and plate is changed,the slope of the regression curve changes accordingly;the same energy corresponds to a bigger discharge quantity.The results are significant enough to be applied in the estimation of the discharge quantity by measuring RF partial discharge signals.
引用
收藏
页码:1828 / 1833
页数:6
相关论文
共 15 条
  • [1] Tang Ju,Zhou Qian,Tang Ming,et al.Study on mathematical modelfor VHF partial discharge of typical insulated defects in GIS. IEEETrans on Dielectrics and Electrical Insulation . 2007
  • [2] Reid A J,Yang L.An integrated measurement strategy for si multaneous fault identification:combining the UHF and IEC60270techniques. Proceedings of the XI Vth Interna-tional Symposium on High Voltage Engineering . 2005
  • [3] A. G. Sellars.Calibration the UHF Technique of Partial Discharge Using a PD Simulator. IEEE Trans, on Dielectrics and Electrical Insulation . 1995
  • [4] Bell R,Charlson C,Halliday S P,et al.High-voltage onsite commissioning tests for gas-insulated substations using UHF partial discharge detection. IEEE Transactions on Power De-livery . 2003
  • [5] A. J. Reid,M. D. Judd,B. G. Stewar et al.Correlation between RF energy and IEC60270 apparent charge for selected partial discharge source geometries. 15th International Symposium on High Voltage Engineering . 2007
  • [6] Hikita M,Ohtsuka S,Matsumoto S.Recent trend of thePartial Discharge Measurement Technique Using the UHFElectromagnetic Wave Detection Method. IEEE Trans_actions on Electrical And Electronic Engineering . 2007
  • [7] A. J. Reid,M. D. Judd,B. G. Stewart et al.Frequency distribution of RF energy from PD sources and its application in combined RF and IEC60270 measurements. IEEE Conference onElectrical Insulation and Dielectric Phenomena . 2006
  • [8] Stewart B G,Reid A J,Judd M D,et al.UHF and IEC60270correlation analysis of radiated frequency band measurements on resin insulation void samples. 2007Electrical Insulation Conference and Electrical Manufacturing Expo . 2007
  • [9] Nicholas De Kock,Branko Coric,Ralf Pietsch.UHF PD detection in gas-insulated switchgear -suitability and sensitivity of the UHF method in comparison with the IEC 270 method. IEEE Electrical Insulation Magazine . 1996
  • [10] CLEARY G P,JUDD M D.UHF and current pulse meas-urements of partial discharge activity in mineral oil. IEE Proceedings Science Measurement and Technology . 2006