锦屏—苏南±800kV特高压直流输电工程交流滤波器优化设计(英文)

被引:8
作者
李璟延
张宗鑫
吴方劼
机构
[1] StatePowerEconomicResearchInstitute
关键词
ultra high voltage direct current(UHVDC) transmission; AC filter; system harmonic impedance characteristic; tuning; BP11/BP13; optimizing design;
D O I
暂无
中图分类号
TN713 [滤波技术、滤波器]; TM721.1 [直流制输电];
学科分类号
摘要
In DC transmission systems,AC filters can effectively reduce the hazards of harmonics,and compensate the reactive power requirements of the converters,thus the type and parameter choice of the filters is important.Therefore,based on the system conditions of Jinping-Sunan ±800 kV UHV DC(ultra-high voltage direct current) transmission project and the main harmonics,three types of filters were designed.The parameters of filter components were determined according to the reactive power compensation.By calculating the filter performance and rating,the results show that the parallel tuning with greatly over-currents appears in the low-voltage arm of BP11/13 filter.In order to avoid this kind of danger,a filter named BP11/BP13 is designed.Studies show that this type of filter can fully meet the filter performance requirements and avoid the over-current.It is concluded that the filter BP11/BP13 can reduce the rating of the components and enhance the stability in the long-term operation.
引用
收藏
页码:3224 / 3229
页数:6
相关论文
共 9 条
[1]   ±660kV宁东-山东直流输电工程交流滤波器暂态额定值计算 [J].
但刚 ;
李明 ;
杨俊 .
高电压技术, 2010, 36 (06) :1583-1588
[2]   ±800kV特高压直流输电技术研究 [J].
刘泽洪 ;
高理迎 ;
余军 .
电力建设, 2007, (10) :17-23
[3]   灵宝交流滤波器暂态额定值计算 [J].
马为民 .
高电压技术, 2005, (04) :52-53
[4]   灵宝换流站交流暂态过电压研究 [J].
聂定珍 ;
郑劲 .
高电压技术, 2005, (04) :54-56
[5]   我国高压直流输电工程国产化回顾及现状 [J].
常浩 .
高电压技术, 2004, (11) :3-4+36
[6]   灵宝换流站交流滤波器性能研究 [J].
杨金根 ;
马为民 .
高电压技术, 2004, (11) :60-62
[7]   直流输电换流站交流滤波器稳态额定值研究 [J].
苏炜 ;
马为民 .
高电压技术, 2004, (11) :63-64
[8]   葛南直流滤波器性能研究 [J].
孙中明 .
高电压技术, 2004, (11) :65-66+71
[9]  
±800kV UHVDC transmission project package design re-port—AC filter performance report .2 Beijing Wanglian HVDC Engineering Technology Co Ltd. . 2011