电晕放电脉冲电流波形和相位分布的测量、分析与仿真(英文)

被引:3
作者
Suwarno
机构
[1] School of Electrical Engineering and Informatics
[2] Institut Teknologi
关键词
corona discharge; phase-resolved analysis; sinusoidal voltage; triangular voltage;
D O I
10.13336/j.1003-6520.hve.2011.11.009
中图分类号
TM835 [高电压测量技术];
学科分类号
摘要
<正>Partial discharge(PD) is one of the most important phenomenon in high voltage insulations.In most cases, the appearance of partial discharges is related to insulation defects.Understanding partial discharges is important for diagnosis on insulation condition.Corona discharges appear when extremely high electric field appears on the conductor surface exceeding the electric field strength of the gas.The high electric field may occur at around protrusion with very sharp tip.This paper reported a holistic approach of corona discharge investigation.The needle-plane electrode system was used.The medium between the electrodes was air.The needle was made from steel with radius of curvature of 3μm(Ogura needle).Sinusoidal as well as triangular applied voltages were used.The waveform of the corona discharges was measured using a digital oscilloscope.The corona discharge pulses were measured using a phase-resolved PD measurement system.The system was able to measure the magnitude(q) and phase angle position(φ) of each PD pulses,as well as the number of discharge pulses(n).The role of applied voltage was investigated using phase-resolved analysis of corona discharge pulses through pulse sequence,pulse magnitude and pulse number analysis. Experimental results indicated that corona discharge current waveform was an impulse with rise time of about several ns and the impulse width of about 100 ns.The Fast Fourier Transform analysis indicated that the corona discharge current waveform had several spectrum peaks at frequency of 7.8 MHz,85.9 MHz,109.4 MHz and 195.3 MHz.The experimental results also showed that discharge pulses were concentrated around the peak of applied voltage for both sinusoidal and triangular voltages.The discharge magnitude,as well as its probability of occurrence,was strongly dependent on the instantaneous applied voltage.The shape ofφ-n,as well asφ-q-n PD patterns,were strongly reflected by the shape of applied voltage.In order to get deep understanding of the corona discharge,by utilizing results of the phase-resolved analysis,electrical equivalent circuits of corona discharges were proposed.The electrical equivalent circuit contained capacitances and a spark gap.For deeply understanding of PD phenomenon,computer simulation was done by using the proposed electrical equivalent circuits.The similarity of the measured and simulated PD patterns was assessed by comparing measured and simulated theφ-q-n andφ-n PD patterns.The results indicated that simulated PD patterns similar to those obtained from experiment.
引用
收藏
页码:2655 / 2663
页数:9
相关论文
共 12 条
  • [1] Comparison between void and electrical treeing discharges in polyethylene. Suwarno. 6th International Conference on Properties and Application of Dielectric Materials . 2000
  • [2] Study of corona discharge pattern on high voltage transmission lines for inspecting faulty porcelain insulators. Cheng Y,Li C,Huang X. IEEE Transactions on Power Delivery . 2008
  • [3] Characteristics of negative corona discharge using CWT with and without airflow. Ichikawa N,Okumura K,Takahashi Y. IEEE Transactions on Dielectrics and Electrical Insulation . 2005
  • [4] Particle-triggered prebreakdown phenomena in atmospheric air gap under ac voltage. Hara M,Negara Y,Setoguchi M,et al. IEEE Transactions on Dielectrics and Electrical Insulation . 2005
  • [5] Design dependent slot discharge andvibration sparking on high voltage windings. Liese M,Brown M. IEEETrans.on Dielectrics and Electrical Insulation . 2008
  • [6] Partial discharge due to electrical treeing in polymers: phase-resolved and time-sequence observation and analysis. Suwarno,Suzuoki Y,Komori F,et al. Journal of Physics D Applied Physics . 1996
  • [7] Dielectric Breakdown of Solids. WHITEHEAD S. . 1953
  • [8] Phase relationship of PD pulse in dielectric liquids under ac conditions. Pompili M,Mazetti C,Bartnikas R. IEEE Transactions on Dielectrics and Electrical Insulation . 2000
  • [9] Model of partial discharges in liquids and computer simulation. Suwarno. Research Journal of Applied Sciences . 2009
  • [10] Modeling of partial discharges in the presence of harmonics. Bahadoorsingh S,Rowland S M. 2009 Annual Report Conference on Electrical Insulation and Dielectric Phenom . 2009