Fenton氧化技术处理含苯胺固体废渣的可行性研究

被引:5
作者
胡立芳
姚俊
楼斌
何若
沈东升
机构
[1] 浙江大学环境工程系
[2] 浙江大学环境工程系 杭州
关键词
Fenton; 苯胺; 固体废渣;
D O I
10.13227/j.hjkx.2008.01.015
中图分类号
X705 [固体废物的处理与利用];
学科分类号
083002 ;
摘要
研究了Fenton催化氧化法对工业固体废渣中苯胺的去除效能,优化了其在固相处理体系中的反应条件,并分析了各影响因子的作用机理和综合反应机理及应用的关键控制步骤.结果表明,在固相反应体系中,采用Fenton催化氧化法处理工业固体废渣中苯胺的最佳反应条件为:pH值3.0,50 g渣样中H2O2流加速率为0.51.0 mL.min-1,30%H2O2投加量为1.1 mL.g-1(以干渣计,下同),Fe2+的投加量为0.012 mmol.g-1(以干渣计,下同),分23次投加Fenton试剂,药剂投加完后继续反应30min.在此条件下固体废物中苯胺的去除率达99.86%,从而为后续的稳定化及固化处理和进入安全填埋场进行安全填埋处理提供了前提保障.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 10 条
[1]   国内外苯胺的生产与消费分析 [J].
刘艳杰 ;
丁国荣 ;
赵庆国 .
化工科技市场, 2005, (07) :39-42+38
[2]   Kinetics of aniline degradation by Fenton and electro-Fenton processes [J].
Anotai, Jin ;
Lu, Ming-Chun ;
Chewpreecha, Parichat .
WATER RESEARCH, 2006, 40 (09) :1841-1847
[3]  
A review of classic Fenton’s peroxidation as an advanced oxidation technique[J] . E. Neyens,J. Baeyens.Journal of Hazardous Materials . 2003 (1)
[4]  
Aniline degradation by Electro-Fenton ? and peroxi-coagulation processes using a flow reactor for wastewater treatment[J] . Enric Brillas,Juan Casado.Chemosphere . 2002 (3)
[5]   Mineralization of aniline and 4-chlorophenol in acidic solution by ozonation catalyzed with Fe2+ and UVA light [J].
Sauleda, R ;
Brillas, E .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2001, 29 (02) :135-145
[6]   Oxidation of dichlorvos with hydrogen peroxide using ferrous ion as catalyst [J].
Lu, MC ;
Chen, JN ;
Chang, CP .
JOURNAL OF HAZARDOUS MATERIALS, 1999, 65 (03) :277-288
[7]  
Aniline mineralization by AOP's: anodic oxidation, photocatalysis, electro-Fenton and photoelectro-Fenton processes[J] . Enric Brillas,Eva Mur,Roser Sauleda,Laura Sànchez,José Peral,Xavier Domènech,Juan Casado.Applied Catalysis B, Environmental . 1998 (1)
[8]   Fenton process for treatment of desizing wastewater [J].
Lin, SH ;
Lo, CC .
WATER RESEARCH, 1997, 31 (08) :2050-2056
[9]  
The electrochemical regeneration of Fenton's reagent in the hydroxylation of aromatic substrates: batch and continuous processes[J] . T. Tzedakis,A. Savall,M. J. Clifton.Journal of Applied Electrochemistry . 1989 (6)
[10]  
UV-O3, UV-H2O2, UV-TiO2 and the photo-Fenton reaction - comparison of advanced oxidation processes for wastewater treatment .2 Ruppert G,Bauer R,Heisler G. Chemosphere . 1994