摘要
Objective To explore the safety and efficacy of frameless stereotactic brain biopsy.Methods Diagnostic accuracy was calculated by comparing biopsy diagnosis with definitive pathology in 62 patients who underwent frameless stereotactic brain biopsy between January 2008 and December 2010 in Xiamen University Southeast Hospital.Preoperative characteristics and histological diagnosis were reviewed and then information was analysed to identify factors associated with the biopsy not yielding a diagnosis and complications.Results Diagnostic yield was 93.5%.No differences were found between pathological diagnosis and frozen pathological diagnosis.The most common lesions were astrocytic lesions,included 16 cases of low-grade glioma and 12 cases of malignant glioma.Remote hemorrhage,metastasis,and lymphoma were following in incidence.Multiple brain lesions were found in 17 cases (27.4%).Eleven cases were frontal lesions (17.7%),8 were frontotemporal (12.9%),6 were frontoparietal (9.7%),and 5 each were temporal,parietal,and parietotemporal lesions (8.1%).Postoperative complications occurred in 21.0% of the patients after biopsies,including 10 haemorrhages (16.1%) and 3 temporary neurological deficits (1 epilepsy,1 headache,and 1 partial hemiparesis).No patient required operation for hematoma evacuation.Conclusion Frameless stereotactic biopsy is an effective and safe technique for histologic diagnosis of brain lesions,particularly for multifocal and frontal lesions.
引用
收藏
页码:113 / 116
页数:4
相关论文
共 6 条
  • [1] Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle[J] . Christopher M. Owen,Mark E. Linskey. Journal of Neuro-Oncology . 2009 (1)
  • [2] Safety and efficacy of frameless and frame-based intracranial biopsy techniques
    Dammers, R.
    Haitsma, I. K.
    Schouten, J. W.
    Kros, J. M.
    Avezaat, C. J. J.
    Vincent, A. J. P. E.
    [J]. ACTA NEUROCHIRURGICA, 2008, 150 (01) : 23 - 29
  • [3] Correlation of diagnostic yield of stereotactic brain biopsy with number of biopsy bits and site of the lesion
    Jain, Deepali
    Sharma, Mehar Chand
    Sarkar, Chitra
    Deb, Prabal
    Gupta, Deepak
    Mahapatra, A. K.
    [J]. BRAIN TUMOR PATHOLOGY, 2006, 23 (02) : 71 - 75
  • [4] Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy
    Smith, JS
    Quiñones-Hinojosa, A
    Barbaro, NM
    McDermott, MW
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2005, 73 (02) : 173 - 179
  • [5] Targeted Brain Biopsy: A Comparison of Freehand Computed Tomography-Guided and Stereotactic Techniques[J] . Dennis Y. Wen,Walter A. Hall,David A. Miller,Edward L. Seljeskog,Robert E. Maxwell. Neurosurgery . 1993 (3)
  • [6] Supratentorial masses: Stereotactic or freehand biopsy?[J] . Timothy Lee,Brendan G. Kenny,Edward R. Hitchock,Peter J. Teddy,Hercules Palividas,William Harkness,Carl H. A. Meyer. British Journal of Neurosurgery . 1991 (4)