Combination of Reactive Current Droop Compensation and Line Drop Compensation for Improving Voltage Stability

被引:2
作者
TIAN QingLIN XiangningSoutheast Shanxi Ultra High Voltage Administrative BureauState Grid Operation Company LimitedChangzhi ChinaDepartment of Electrical EngineeringChina Three Corges UniversityYichang China [1 ,2 ,1 ,47100 ,2 ,443002 ]
机构
关键词
power system stability; voltage control regulator; voltage stability;
D O I
10.13296/j.1001-1609.hva.2009.04.027
中图分类号
TM712 [电力系统稳定];
学科分类号
摘要
Recent events related to power system failure have shown that voltage collapse can be a cause of widespread outages.The thrust of this paper is to discuss and establish means of mitigating system voltage instability by using a combination of both reactive current droop compensation and line drop compensation.It is shown that the point that the voltage regulator controls can be defined by a new method which is based on a widely accepted voltage stability analysis tool.This tool can be used to determine which generators will have an impact on the maximum permissible loading of a bus.Dynamic analysis was carried out on the CIGRE Nordic test system to study the impact of control point location on time to collapse and it is shown that the new scheme can improve the voltage stability.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 19 条
[1]  
Long Term Dynamics Phase II. M.Stubbe. CIGRE TF 38-02-08 . 1995
[2]  
Power Svstem Voltage Stability. TAYLOR C. . 1994
[3]  
Improvement of Voltage Stability by the Advanced High Voltage Control Regulator. KITAMURA H,SHIMOMURA M,PASERBA J. 2000 IEEE Power Engineering Society Summer Meeting . 2000
[4]  
High Side Voltage Control at Manitoba Hydro. DAVIES J B,MIDFORD L E. 2000 IEEE Power Engineering Society Summer Meeting . 2000
[5]  
Closed Loop Testing of a Joint VAR Controller Using a Real Time Simulator. BRANDT D,WACHAL R,VALIQUETTE R,et al. IEEE Transactions on Power Systems . 1991
[6]  
Excitation Control for High Side Voltage Regulation. MURDOCH A,SANCHEZ-GASCA J J,DANTONIO M J. 2000IEEE Power Engineering Society Summer Meeting . 2000
[7]  
Installation and Initial Operating Experiencewith Line Drop Compensation at John Day Powerhouse. KOSTEREV D. IEEE Transactions on Power Systems . 2001
[8]  
Torra-Improve-ments in the Organisation of Secondary Voltage Control in France. PAUL J P,CORROYER C,JEANNEL P,et al. CIGRE Session . 1990
[9]  
Power System Stability and Control. Kundur P. . 1994
[10]  
The Study of a Centralized Voltage Control Method Applicable to theBelgian System. PIRET J P,ANTOINE J P,STUBBE M,et al. http://www.eurostag.be/download/PUBPSO4N5205200100.pdf . 1992