基于故障点电压的单相自适应重合闸判据(英文)

被引:8
作者
李博通
李永丽
机构
[1] KeyLaboratoryofSmartGridofMinistryofEducation,TianjinUniversity
关键词
adaptive single-pole autoreclosure; fault location; permanent fault; transient fault; fault point voltage;
D O I
暂无
中图分类号
TM762.2 [自动重合闸];
学科分类号
080802 ;
摘要
A new adaptive single-pole autoreclosure technique based on the magnitude of fault point voltage is presented.After fault phase tripping,the fault point voltage of transient faults is essentially different from that of permanent faults,so the magnitude of fault point voltage is used to distinguish fault nature.Fault point voltage can be calculated through uniform transmission line equation.Considering that fault point voltage changes with fault location and transition resistance,a concept of real-time action voltage setting is put forward.The technique solves the problem that criterions based on terminal voltage could be easily affected by inductive coupling voltage and transition resistance.Simulation results show that the method is reliable.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 9 条
[1]   带并联电抗器的超高压输电线路自适应重合闸新判据 [J].
李博通 ;
李永丽 .
电力系统自动化, 2009, 33 (23) :48-54
[2]   特高压长线路单相自适应重合闸的新原理 [J].
郭征 ;
贺家李 ;
王俊 .
高电压技术, 2009, 35 (05) :1005-1008
[3]   基于准测距结果的输电线单相故障性质识别 [J].
刘俊岭 ;
刘汉青 ;
刘浩芳 .
电网技术, 2009, 33 (08) :84-86+107
[4]   基于改进型相关法的单相自适应重合闸新判据 [J].
王增平 ;
刘浩芳 ;
徐岩 ;
刘俊岭 .
中国电机工程学报, 2007, (10) :49-55
[5]   带并联电抗器输电线路单相自动重合闸永久故障的识别原理研究 [J].
索南加乐 ;
孙丹丹 ;
付伟 ;
王向兵 ;
刘文涛 ;
焦在滨 .
中国电机工程学报, 2006, (11) :75-81
[6]   带并联电抗器的超高压输电线单相自适应重合闸的研究 [J].
李斌 ;
李永丽 ;
盛鹍 ;
曾治安 .
中国电机工程学报, 2004, (05) :56-60
[7]   基于故障测距的单相自动重合闸永久故障电压自适应补偿判据 [J].
索南加乐 ;
刘辉 ;
吴亚萍 ;
毛鹏 ;
杜肖功 .
中国电机工程学报, 2004, (04) :84-88
[8]   单相自适应重合闸相位判据的研究 [J].
李斌 ;
李永丽 ;
黄强 ;
翟永昌 ;
曾治安 ;
马志宇 ;
贺家李 .
电力系统自动化, 2003, (22) :41-44
[9]  
The principle of total potential energy with stationary value in elastic system dynamics and its application to the analysis of vibration and dynamic stability .2 Zeng Qingyuan,Lou Ping,Xiang Jun. Journal of Huazhong University of Science and Technology . 2002