臼假体位置对全髋关节置换术后假体受力及磨损的影响

被引:4
作者
杨显春
朱振安
机构
[1] 上海交通大学医学院附属第九人民医院骨科
关键词
全髋置换术; 臼假体位置; 受力; 磨损;
D O I
暂无
中图分类号
R687.4 [关节手术];
学科分类号
100220 [骨科学];
摘要
全髋关节置换时臼假体的位置安放不当可导致术后脱位、增加骨-假体的应力,加快假体磨损。髋臼假体安放于轻度内上的位置可增加骨-假体界面的接触,从而降低了接触面应力,临床预后更好。计算机辅助导航系统广泛用于骨科手术中,它对空间长度和角度的定位有很好的精度。髋臼假体的外展角和前倾角显著影响THA术后假体的受力及磨损。本文还简要回顾了超高分子量聚乙烯材料磨损机制的研究进展。
引用
收藏
页码:332 / 336
页数:5
相关论文
共 11 条
[1]
High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty - A review of the PCA, the Harris Galante and the profile/tri-lock plus arthroplasties with a minimum of 12 years median follow-up in 96 hips [J].
Hallan, Geir ;
Lie, Stein A. ;
Havelin, Leif I. .
ACTA ORTHOPAEDICA, 2006, 77 (04) :575-584
[2]
A new CT method for measuring cup orientation after total hip arthroplasty - A study of 10 patients [J].
Olivecrona, H ;
Weidenhielm, L ;
Olivecrona, L ;
Beckman, MO ;
Stark, A ;
Noz, ME ;
Maguire, GQ ;
Zeleznik, MP ;
Svensson, L ;
Jonson, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (03) :252-260
[3]
A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[4]
Load transfer and fixation mode of press-fit acetabular sockets [J].
Widmer, KH ;
Zurfluh, B ;
Morscher, EW .
JOURNAL OF ARTHROPLASTY, 2002, 17 (07) :926-935
[5]
Average patient walking activity approaches 2 million cycles per year.[J].Mauricio Silva;Eric F. Shepherd;Walter O. Jackson;Frederick J. Dorey;Thomas P. Schmalzried.The Journal of Arthroplasty.2002, 6
[6]
Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene - A survey of 8 reports in the literature [J].
Oparaugo, PC ;
Clarke, IC ;
Malchau, H ;
Herberts, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (01) :22-28
[7]
Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534
[8]
Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements.[J].A Wang;A Essner;V.K Polineni;C Stark;J.H Dumbleton.Tribology International.1998, 1
[9]
Effect of superior and superolateral relocations of the hip center on hip joint forces.[J].T.C. Doehring;H.E. Rubash;F.J. Shelley;L.J. Schwendeman;T.K. Donaldson;Y.A. Navalgund.The Journal of Arthroplasty.1996, 6
[10]
LOAD-TRANSFER ACROSS THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :715-724