基于光纤光栅传感器的变压器内部温度测量技术(英文)

被引:22
作者
刘军 [1 ]
陈伟根 [1 ]
赵建保 [2 ]
机构
[1] State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University
[2] Luoyang Power Supply
关键词
FBG sensor; hot-spot temperature; power transformer; temperature measurement; winding temperature; load test;
D O I
10.13336/j.1003-6520.hve.2009.03.040
中图分类号
TM406 [试验、运行];
学科分类号
摘要
Thermal modeling of the power transformer to estimate the internal temperature only reflects the winding hot spot to a certain extent. The application of optical fiber sensors to measure transformer internal temperature directly can obtain the true temperature with high accuracy and stability and overcome the shortcomings of traditional electric sensors. It analyses the measuring principle of FBG(fiber bragg grating)sensor, and constructs transformer internal temperature measurement platform with FBG temperature sensors, then adopt short-circuit method to simulate the process of winding heat under different load conditions. Finally the measurement of transformer internal temperature is conducted respectively with FBG temperature sensors and thermocouples. Comparison and analysis of the results shows that FBG sensors can effectively measure the internal temperature of the transformer.
引用
收藏
页码:539 / 543
页数:5
相关论文
共 6 条
[1]   基于F-P滤波器的光纤光栅解调和标定 [J].
柏俊杰 ;
王立新 ;
冉昌艳 ;
陈念军 .
传感器与微系统, 2006, (03) :10-11+14
[2]   变压器绕组热点温度在线测量方法的研究 [J].
应勇 ;
刘富家 .
东北电力技术, 2002, (09) :17-19
[3]   一种变压器绕组温度测量方法 [J].
冯悦波 .
变压器, 2001, (05) :13-15
[4]   变压器绕组热点在线监测装置的研制与应用 [J].
陈淑谨 ;
王世阁 ;
刘富家 .
变压器, 2000, (08) :41-45
[5]  
IECloading guide for oil-i mmersed powertransformers. IEC354 . 1991
[6]  
Prediction of top-oil temperature for transformers using neural networks. Qing H,Si J,Tylavsky J D. IEEE Transactions on Power Delivery . 2000