Is Cemented Dual-Mobility Cup a Reliable Option in Primary and Revision Total Hip Arthroplasty: A Systematic Review

被引:7
作者
Ciolli, Gianluca [1 ,2 ]
Mesnard, Guillaume [1 ]
Deroche, Etienne [1 ]
Gunst, Stanislas [1 ,3 ]
Batailler, Cecile [1 ,3 ]
Servien, Elvire [1 ,4 ]
Lustig, Sebastien [1 ,3 ]
机构
[1] Lyon North Univ Hosp, Hop La Croix Rousse, Orthopaed Dept, Hosp Civils Lyon, 103 Grande Rue Croix Rousse, F-69004 Lyon, France
[2] Sacred Heart Catholic Univ, Fdn Policlin Univ A Gemelli IRCCS, Orthopaed & Traumatol, I-00168 Rome, Italy
[3] Claude Bernard Lyon 1 Univ, Univ Lyon, IFST TAR, LBMC UMR T9406, F-69622 Lyon, France
[4] Claude Bernard Lyon 1 Univ, Interuniv Lab Biol Mobil, EA LIBM 7424, F-69622 Lyon, France
关键词
hip arthroplasty; dual mobility cup; cemented dual mobility; dislocation; instability; hip revision; FEMORAL-NECK FRACTURES; RECURRENT DISLOCATIONS; EARLY COMPLICATIONS; RISK; THA; REINFORCEMENT; OUTCOMES; SOCKET; RECONSTRUCTION; REPLACEMENT;
D O I
10.3390/jpm13010081
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
100404 [儿少卫生与妇幼保健学];
摘要
Background: Instability is a common complication following total hip arthroplasty (THA). The dual mobility cup (DMC) allows a reduction in the dislocation rate. The goal of this systematic review was to clarify the different uses and outcomes according to the indications of the cemented DMC (C-DMC). Methods: A systematic review was performed using the keywords "Cemented Dual Mobility Cup" or "Cemented Tripolar Cup" without a publication year limit. Of the 465 studies identified, only 56 were eligible for the study. Results: The overall number of C-DMC was 3452 in 3426 patients. The mean follow-up was 45.9 months (range 12-98.4). In most of the cases (74.5%) C-DMC was used in a revision setting. In 57.5% DMC was cemented directly into the bone, in 39.6% into an acetabular reinforcement and in 3.2% into a pre-existing cup. The overall dislocation rate was 2.9%. The most frequent postoperative complications were periprosthetic infections (2%); aseptic loosening (1.1%) and mechanical failure (0.5%). The overall revision rate was 4.4%. The average survival rate of C-DMC at the last follow-up was 93.5%. Conclusions: C-DMC represents an effective treatment option to limit the risk of dislocations and complications for both primary and revision surgery. C-DMC has good clinical outcomes and a low complication rate.
引用
收藏
页数:24
相关论文
共 87 条
[1]
Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up [J].
Acker, A. ;
Fischer, J. -F. ;
Aminian, K. ;
Lecureux, E. ;
Jones, B. M. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (01) :21-25
[2]
Revision total hip arthroplasty with a Kerboull plate: comparative outcomes using standard versus dual mobility cups [J].
Assi, Chahine ;
Caton, Jacques ;
Fawaz, Wissam ;
Samaha, Camille ;
Yammine, Kaissar .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (10) :2245-2251
[3]
The evolution of outcomes and indications for the dual-mobility cup: a systematic review [J].
Batailler, Cecile ;
Fary, Camdon ;
Verdier, Regis ;
Aslanian, Thierry ;
Caton, Jacques ;
Lustig, Sebastien .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) :645-659
[4]
Cementation of a dual mobility cup in a well-fixed acetabular component- a reliable option in revision total hip arthroplasty? [J].
Bellova, Petri ;
Koch, Fiona ;
Stiehler, Maik ;
Hartmann, Albrecht ;
Fritzsche, Hagen ;
Guenther, Klaus-Peter ;
Goronzy, Jens .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[5]
Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures [J].
Bensen, Anne S. ;
Jakobsen, Thomas ;
Krarup, Niels .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (06) :1241-1245
[6]
Dual mobility total hip arthroplasty: should everyone get one? [J].
Blakeney, William G. ;
Epinette, Jean-Alain ;
Vendittoli, Pascal-Andre .
EFORT OPEN REVIEWS, 2019, 4 (09) :541-547
[7]
Surgical Technique: A Cup-in-Cup Technique to Restore Offset in Severe Protrusio Acetabular Defects [J].
Blumenfeld, Thomas J. ;
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :435-441
[8]
Dual mobility cups in total hip arthroplasty after failed internal fixation of proximal femoral fractures [J].
Boulat, Sandrine ;
Neri, Thomas ;
Boyer, Bertrand ;
Philippot, Remi ;
Farizon, Frederic .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (03) :491-495
[9]
Bousquet G., 1985, J Orthop Surg Tech, V1, P15
[10]
Influence of dual-mobility acetabular implants on revision and survivorship of cup and Kerboull-type reinforcement ring constructs in aseptic acetabular loosening [J].
Bozon, Olivier ;
Dagneaux, Louis ;
Sanchez, Thomas ;
Gaillard, Florent ;
Hamoui, Mazen ;
Canovas, Francois .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (02)