Cardiac MR imaging: A guide for the beginner

被引:15
作者
Boxt, LM [1 ]
机构
[1] Beth Israel Med Ctr, Dept Radiol, New York, NY 10003 USA
关键词
aorta; dissection; heart; diseases; MR; ventricles; pericardium;
D O I
10.1148/radiographics.19.4.g99jl161009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The complex motion of the heart during contraction is a serious challenge to the diagnostic radiologist and to the capabilities of the magnetic resonance (MR) imaging unit itself, but electrocardiographic (ECG) gating "stops" motion and thus allows acquisition of diagnostic-quality images. Attention to placement of chest-wall ECG electrodes and the course of ECG leads from the patient will maximize the quality of the gating signal and result in better-quality images. Before commencing the MR imaging examination, the clinical questions for the examination must be identified so that a clinical protocol can be applied to acquire relevant morphologic and physiologic data. In addition to the standard orthogonal views (axial, coronal, and sagittal), oblique and complex sections parallel and orthogonal to intrinsic cardiac axes may be necessary to portray the relevant anatomy to best advantage. Construction of these views requires an understanding of basic normal and pathologic cardiac anatomy. If care is taken in the planning and execution of the MR imaging examination, the radiologist will be able to exploit this exciting technology to its full noninvasive potential.
引用
收藏
页码:1009 / 1025
页数:17
相关论文
共 25 条
[1]   GATED MRI OF CARDIAC AND PARACARDIAC MASSES - INITIAL EXPERIENCE [J].
AMPARO, EG ;
HIGGINS, CB ;
FARMER, D ;
GAMSU, G ;
MCNAMARA, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1151-1156
[2]  
Boxt L M, 1996, Magn Reson Imaging Clin N Am, V4, P327
[3]  
Boxt L M, 1996, Magn Reson Imaging Clin N Am, V4, P253
[4]   DIRECT QUANTITATION OF RIGHT AND LEFT-VENTRICULAR VOLUMES WITH NUCLEAR-MAGNETIC-RESONANCE IMAGING IN PATIENTS WITH PRIMARY PULMONARY-HYPERTENSION [J].
BOXT, LM ;
KATZ, J ;
KOLB, T ;
CZEGLEDY, FP ;
BARST, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1508-1515
[5]   OPTIMIZING ELECTROCARDIOGRAPH ELECTRODE PLACEMENT FOR CARDIAC-GATED MAGNETIC-RESONANCE-IMAGING [J].
DIMICK, RN ;
HEDLUND, LW ;
HERFKENS, RJ ;
FRAM, EK ;
UTZ, J .
INVESTIGATIVE RADIOLOGY, 1987, 22 (01) :17-22
[6]   ALTERATIONS IN THE RAT ELECTROCARDIOGRAM INDUCED BY STATIONARY MAGNETIC-FIELDS [J].
GAFFEY, CT ;
TENFORDE, TS .
BIOELECTROMAGNETICS, 1981, 2 (04) :357-370
[7]   EFFECT OF 1.5 TESLA NUCLEAR-MAGNETIC-RESONANCE IMAGING SCANNER ON IMPLANTED PERMANENT PACEMAKERS [J].
HAYES, DL ;
HOLMES, DR ;
GRAY, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :782-786
[8]   ESTIMATION OF RIGHT VENTRICULAR MASS IN NORMAL SUBJECTS AND IN PATIENTS WITH PRIMARY PULMONARY-HYPERTENSION BY NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
KATZ, J ;
WHANG, J ;
BOXT, LM ;
BARST, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (06) :1475-1481
[9]  
KAUFFMAN RE, 1992, PEDIATRICS, V89, P1110
[10]   INVIVO MEASUREMENT OF MYOCARDIAL MASS USING NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
KELLER, AM ;
PESHOCK, RM ;
MALLOY, CR ;
BUJA, LM ;
NUNNALLY, R ;
PARKEY, RW ;
WILLERSON, JT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) :113-117