Autoassembly Protein Arrays for Analyzing Antibody Cross-Reactivity

被引:36
作者
Gaster, Richard S. [2 ,3 ]
Hall, Drew A.
Wang, Shan X. [1 ,4 ]
机构
[1] Stanford Univ, Geballe Lab Adv Mat, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[3] Stanford Univ, Med Scientist Training Program, Sch Med, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Mat Sci & Engn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
Biosensors; nanobiotechnology; antibody cross-reactivity; giant magnetoresistance; magnetic nanoparticles; SPIN-VALVE SENSORS; MICROARRAYS; PROTEOMICS; ANTIGEN;
D O I
10.1021/nl1026056
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We report an autoassembly protein array capable of rapidly screening for aberrant antibody-antigen binding events. Our technique combines magnetic nanoparticle technology with proximity-based, magnetically responsive nanosensors for rapid (under 15 min) and high-density screening of antibody cross-reactivity at sensitivities down to 50 fM in a homogeneous assay. This method will enable the identification of the precise cause of aberrant or cross-reactive binding events in an easy-to-use, rapid, and high-throughput manner.
引用
收藏
页码:2579 / 2583
页数:5
相关论文
共 21 条
[1]   Protein microarrays for multiplex analysis of signal transduction pathways [J].
Chan, SM ;
Ermann, J ;
Su, L ;
Fathman, CG ;
Utz, PJ .
NATURE MEDICINE, 2004, 10 (12) :1390-1396
[2]   Cross-reactivity of antibodies immunoadsorbed to laminin with recombinant human La (SS-B) protein [J].
Chang, SH ;
Huh, MS ;
Kim, HR ;
Kim, IS ;
Kim, S ;
Lee, JS ;
Semsei, I ;
Grolz, D ;
Bachmann, M .
JOURNAL OF AUTOIMMUNITY, 1998, 11 (02) :163-167
[3]   TROP2: a novel prognostic marker in squamous cell carcinoma of the oral cavity [J].
Fong, Dominic ;
Spizzo, Gilbert ;
Gostner, Johanna M. ;
Gastl, Guenther ;
Moser, Patrizia ;
Krammel, Clemens ;
Gerhard, Stefan ;
Rasse, Michael ;
Laimer, Klaus .
MODERN PATHOLOGY, 2008, 21 (02) :186-191
[4]   Matrix-insensitive protein assays push the limits of biosensors in medicine [J].
Gaster, Richard S. ;
Hall, Drew A. ;
Nielsen, Carsten H. ;
Osterfeld, Sebastian J. ;
Yu, Heng ;
Mach, Kathleen E. ;
Wilson, Robert J. ;
Murmann, Boris ;
Liao, Joseph C. ;
Gambhir, Sanjiv S. ;
Wang, Shan X. .
NATURE MEDICINE, 2009, 15 (11) :1327-U130
[5]  
Gershon D, 2002, NATURE, V416, P885, DOI 10.1038/416885a
[6]   Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications [J].
Graham, DL ;
Ferreira, H ;
Bernardo, J ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) :7786-7788
[7]   GMR biosensor arrays: A system perspective [J].
Hall, D. A. ;
Gaster, R. S. ;
Lin, T. ;
Osterfeld, S. J. ;
Han, S. ;
Murmann, B. ;
Wang, S. X. .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) :2051-2057
[8]   ANTIBODIES AGAINST A NONAPEPTIDE OF POLYOMAVIRUS MIDDLE T-ANTIGEN - CROSS-REACTION WITH A CELLULAR PROTEIN(S) [J].
ITO, Y ;
HAMAGISHI, Y ;
SEGAWA, K ;
DALIANIS, T ;
APPELLA, E ;
WILLINGHAM, M .
JOURNAL OF VIROLOGY, 1983, 48 (03) :709-720
[9]   Quantitative Serum Proteomics from Surface Plasmon Resonance Imaging [J].
Lausted, Christopher ;
Hu, Zhiyuan ;
Hood, Leroy .
MOLECULAR & CELLULAR PROTEOMICS, 2008, 7 (12) :2464-2474
[10]   Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications [J].
Li, GX ;
Joshi, V ;
White, RL ;
Wang, SX ;
Kemp, JT ;
Webb, C ;
Davis, RW ;
Sun, SH .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :7557-7559