Physics of ultrasonic surgery using tissue fragmentation .2.

被引:35
作者
Bond, LJ
Cimino, WW
机构
[1] UNIV COLORADO,CTR ACOUST MECH & MAT,BOULDER,CO
[2] VALLEYLAB INC,PFIZER HOSP PROD GRP,BOULDER,CO
关键词
ultrasonic surgery; low frequency; phaco-emulsification; tissue fragmentation; aspiration;
D O I
10.1016/0301-5629(95)02022-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic surgical aspirators typically operate at a frequency between 20 and 60 kHz. A vibrating hollow horn moves against the tissue and suction is applied, The interaction causes tissue to fragment; the fragmented material is then aspirated, However, the mechanism of interaction is poorly understood: the most common view relates it to cavitation, probably active in concert with other mechanisms, including the direct jack-hammer effect, shock-induced stress, acoustic microstreaming and shearing stress, It has also been attributed to chopping, which will produce emulsification. This article reports a study that collected and analyzed ultrasonic, high-speed photographic, visual/optical and electrical data for a 23-kHz unit operating in water and a range of fresh pig tissues. The primary mechanism for tissue fragmentation is shown to be horn-tip impact and other mechanical forces, operating in combination with hydrodynamic forces applied to the tissue on the forward stroke in each cycle, No evidence of cavitation in tissue was observed.
引用
收藏
页码:101 / 117
页数:17
相关论文
共 40 条
[1]   ULTRASONIC DEBRIDEMENT OF ROOT CANALS - ACOUSTIC CAVITATION AND ITS RELEVANCE [J].
AHMAD, M ;
FORD, TRP ;
CRUM, LA ;
WALTON, AJ .
JOURNAL OF ENDODONTICS, 1988, 14 (10) :486-493
[2]  
[Anonymous], 113 NCRP
[3]  
[Anonymous], 1988, ULTRASOUND ITS CHEM
[4]  
Balamuth L, 1970, US Patent, Patent No. [3 526 219, 3526219]
[5]  
BEISSNER K, 1980, VDE ASS GERMAN ELECT, V80, P567
[6]   HISTOLOGICAL APPEARANCES OF INTRACRANIAL BIOPSIES OBTAINED USING THE CAVITRON ULTRASONIC SURGICAL ASPIRATOR [J].
BLACKIE, RAS ;
GORDON, A .
JOURNAL OF CLINICAL PATHOLOGY, 1984, 37 (10) :1101-1104
[7]  
BROWN LL, 1993, MODIFIED SPARK GAP L
[8]   LYSIS OF CELLS IN ELODEA LEAVES BY PULSED AND CONTINUOUS WAVE ULTRASOUND [J].
CARSTENSEN, EL ;
CHILD, SZ ;
CRANE, C ;
MILLER, MW ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (02) :167-173
[9]   A NEW MOTOR-DRIVEN SURGICAL PROBE AND ITS INVITRO COMPARISON WITH THE CAVITRON ULTRASONIC SURGICAL ASPIRATOR [J].
CHAN, KK ;
WATMOUGH, DJ ;
HOPE, DT ;
MOIR, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (04) :279-283
[10]  
CHIANG CH, 1994, P FAR E C NDT FENDT, P449