Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals .2.

被引:74
作者
Thompson, SA
Dummer, PMH
机构
[1] Department of Restorative Dentistry, Univ. of Wales College of Medicine, Cardiff
[2] Department of Restorative Dentistry, Dental School, Univ. of Wales College of Medicine, Cardiff CF4 4XY, Heath Park
关键词
canal shaping; endodontics; nickel-titanium; root canals; rotary files;
D O I
10.1111/j.1365-2591.1997.tb01092.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine the shaping ability of ProFile,04 Taper Series 29 rotary nickel-titanium instruments in simulated canals, A total of 40 simulated root canals made up of four different shapes in terms of angle and position of curvature were prepared by Profile instruments using a step-down approach, Part 2 of this two-part report describes the efficacy of the instruments in terms of prevalence of canal aberrations, the amount and direction of canal transportation and the overall postoperative shape, No zips, perforations or danger zones were created although 24 specimens (60%) had ledges on the outer wall of the canal, The incidence of ledges differed significantly (P < 0.001) between the canal shapes, At specific points along the canal length there were highly significant differences (P < 0.001) in total canal width and in the amount of material removed fi om the inner and outer aspects of the curve between the various canal shapes. Overall, 40 degrees canals were wider than 20 degrees canals and canals with curves which began 8 mm fi om the orifice were wider than 12 mm canals, The direction of canal transportation at the end-point of preparation was balanced between inner and outer in the 8 mm canals, but more often towards the outer in the 12 mm canals, At the apex of the curve, transportation was invariably towards the outer aspect of the curvature, At the beginning of the curve, transportation was more balanced between inner and outer, Mean absolute transportation, ignoring direction, was generally greater in 40 degrees canals and in those with the curve beginning 8 mm from the orifice. Of particular importance was the finding that excessive resin was removed from the outer aspect of the canal at the apex of the curve which was often associated with irregular widened areas or ledges, This is in contrast to the pattern of tissue removal found with stainless steel hand instruments where more resin is removed fi om the inner aspect of the canal at the apex, to create a danger zone.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 20 条
[1]   THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL [J].
ABOURASS, M ;
FRANK, AL ;
GLICK, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) :792-794
[3]   A COMPARISON OF THE ABILITY OF K-FILES AND HEDSTROM FILES TO SHAPE SIMULATED ROOT CANALS IN RESIN BLOCKS [J].
ALODEH, MHA ;
DUMMER, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1989, 22 (05) :226-235
[4]  
ALOMARI MAO, 1992, INT ENDOD J, V25, P57, DOI 10.1111/j.1365-2591.1992.tb00738.x
[5]  
ALOMARI MAO, 1992, INT ENDOD J, V21, P67
[6]  
DUMMER PMH, 1993, INT ENDOD J, V26, P159
[7]   A METHOD FOR THE CONSTRUCTION OF SIMULATED ROOT CANALS IN CLEAR RESIN BLOCKS [J].
DUMMER, PMH ;
ALODEH, MHA ;
ALOMARI, MAO .
INTERNATIONAL ENDODONTIC JOURNAL, 1991, 24 (02) :63-66
[8]  
DUMMER PMH, 1989, INT ENDOD J, V5, P211
[9]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[10]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151