Impact of small prosthetic valve size on operative mortality in elderly patients after aortic valve replacement for aortic stenosis: Does gender matter?

被引:33
作者
Adams, DH
Chen, RH
Kadner, A
Aranki, SF
Allred, EN
Cohn, LH
机构
[1] Brigham & Womens Hosp, Div Cardiac Surg, Boston, MA 02115 USA
[2] Boston Childrens Hosp, Neuroepidemiol Unit, Boston, MA USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
D O I
10.1016/S0022-5223(99)70050-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Ideal management of the elderly patient with a small aortic root remains controversial. This retrospective analysis was performed to determine whether small prosthetic valve size is related to outcome in patients 70 years of age or older undergoing aortic valve replacement for aortic stenosis. Methods: Between December 1991 and July 1998, 366 patients 70 years of age or older (median age 77 years, range 73-81 years, 49% male) underwent isolated aortic valve replacement or aortic valve replacement with coronary bypass grafting with standard Carpentier-Edwards bovine pericardial valves (Baxter Healthcare Corp, Edwards Division, Santa Ana, Calif) (n = 277; 76%) or St Jude Medical mechanical valves (St Jude Medical, Inc, St Paul, Minn) (n = 89; 24%). Propensity scoring and multivariable regression models were used to evaluate the risks associated,vith implantation of 19-mm valves. Results: Operative mortality was 16.7 % (17/102) in patients who received 19-mm valves and 3% (8/264) among those receiving greater than or equal to 21-mm valves (P less than or equal to .0005). The univariable odds ratio for operative death for 19-mm versus greater than or equal to 21-mm valves was 6.4 (95% CI 2.7, 15.4; P less than or equal to .0005). Zn the final multivariable model, receipt of a 19-mm valve alone was not a statistically significant predictor of operative death (odds ratio 2.1; 95% CI 0.7, 6.4; P = .21). However, the combination of male sex and 19-mm valve resulted in a significant risk of operative death (4/9 patients; odds ratio 17.5; 95% CI 2.2, 139; P = .007). Use of a 19-mm valve was not related to late death in either the univariable (hazard ratio 1.0; 95% CI 0.5, 2.0; P = .95) or the multivariable analysis (hazard ratio 0.7; 95% CI 0.3, 1.8; P = .51). Conclusions: Implantation of a standard 19-mm aortic valve in elderly men with aortic stenosis may be associated with an increased risk of operative mortality. A higher performance valve and/or a root enlargement procedure should be considered in men with a measured 19-mm anulus.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 31 条
  • [1] ARANKI SF, 1993, CIRCULATION, V88, P17
  • [2] CARROLL JD, 1992, CIRCULATION, V86, P1099, DOI 10.1161/01.CIR.86.4.1099
  • [3] Christakis GT, 1997, ANN THORAC SURG, V63, P933
  • [4] The impact of age, coronary artery disease, and cardiac comorbidity on late survival after bioprosthetic aortic valve replacement
    Cohen, G
    David, TE
    Ivanov, J
    Armstrong, S
    Feindel, CM
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (02) : 273 - 282
  • [5] AORTIC-VALVE REPLACEMENT WITH HANCOCK PORCINE XENOGRAFT
    COHN, LH
    SANDERS, JH
    COLLINS, JJ
    [J]. ANNALS OF THORACIC SURGERY, 1976, 22 (03) : 221 - 227
  • [6] David T E, 1992, J Heart Valve Dis, V1, P244
  • [7] Aortic valve replacement with cryopreserved aortic allograft: Ten-year experience
    Doty, JR
    Salazar, JD
    Liddicoat, JR
    Flores, JH
    Doty, DB
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (02) : 371 - 379
  • [8] FISHER LD, 1982, J THORAC CARDIOV SUR, V84, P334
  • [9] VALVE-REPLACEMENT IN NARROW AORTIC ROOTS - SERIAL HEMODYNAMICS AND LONG-TERM CLINICAL OUTCOME
    FOSTER, AH
    TRACY, CM
    GREENBERG, GJ
    MCINTOSH, CL
    CLARK, RE
    [J]. ANNALS OF THORACIC SURGERY, 1986, 42 (05) : 506 - 516
  • [10] GILL CC, 1982, CIRCULATION S, V66, P47