Risk factors for intraoperative lateral mass fracture of lateral mass screw fixation in the subaxial cervical spine Clinical article

被引:15
作者
Inoue, Shinichi [1 ]
Moriyama, Tokuhide [1 ]
Tachibana, Toshiya [1 ]
Okada, Fumiaki [1 ]
Maruo, Keishi [1 ]
Horinouchi, Yutaka [1 ]
Yoshiya, Shinichi [1 ]
机构
[1] Hyogo Coll Med, Dept Orthopaed Surg, Nishinomiya, Hyogo 6638501, Japan
关键词
lateral mass; cervical; spinal fusion; complication; fracture; STAGE RENAL-DISEASE; DESTRUCTIVE SPONDYLOARTHROPATHY; HEMODIALYSIS-PATIENTS; ROY-CAMILLE; PLATE; RECONSTRUCTION; STABILIZATION; COMPLICATIONS; ARTHRODESIS; PLACEMENT;
D O I
10.3171/2013.9.SPINE121055
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Object. Although lateral mass screw fixation for the cervical spine is a safe technique, lateral mass fracture during screw fixation is occasionally encountered intraoperatively. This event is regarded as a minor complication; however, it poses difficulties in management that may affect fixation stability and clinical outcome. The purpose of this study is to determine the incidence and etiology of lateral mass fractures during cervical lateral mass screw fixation. Methods. A retrospective clinical review of patient records was performed in 117 consecutive patients (mean age 57 years, range 15-86 years) who underwent lateral mass screw fixation using a modified Magerl method from 1997 to 2010 at a single institution. A total of 555 lateral masses were included in this study. The outer diameters of the screws were 3.5 or 4.0 mm. In the retrospective clinical analysis, the incidence of intraoperative lateral mass fractures was reviewed. Potential risk factors for this complication were assessed using multivariate analysis. Results. The incidence of lateral mass fractures during cervical lateral mass screw fixation was 4.7% (26 lateral masses) among all cases. Among the disorders, the incidence was highest in patients with destructive spondyloarthropathy (DSA) (18.8%, 12 lateral masses). There was no significant difference with respect to lateral mass fracture between the use of 4.0-mm screws (5.6%) and 3.5-mm screws (3.6%). Independent risk factors identified by logistic regression were DSA (OR 7.89, p < 0.001) and screw insertion in the C-6 lateral masses (OR 2.80, p = 0.018). Conclusions. The overall incidence of lateral mass fracture during cervical lateral mass screw fixation was 4.7%. Destructive spondyloarthropathy as an underlying cause of morbidity and screw placement in the C-6 lateral mass were identified as independent risk factors. Use of a 4.0-mm screw in patients with DSA may be a principal risk factor for this complication.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 29 条
[1]
Increased risk of hip fracture among patients with end-stage renal disease [J].
Alem, AM ;
Sherrard, DJ ;
Gillen, DL ;
Weiss, NS ;
Beresford, SA ;
Heckbert, SR ;
Wong, C ;
Stehman-Breen, C .
KIDNEY INTERNATIONAL, 2000, 58 (01) :396-399
[2]
ANATOMIC CONSIDERATIONS FOR PLATE-SCREW FIXATION OF THE CERVICAL-SPINE [J].
AN, HS ;
GORDIN, R ;
RENNER, K .
SPINE, 1991, 16 (10) :S548-S551
[3]
POSTERIOR CERVICAL ARTHRODESIS WITH AO RECONSTRUCTION PLATES AND BONE-GRAFT [J].
ANDERSON, PA ;
HENLEY, MB ;
GRADY, MS ;
MONTESANO, PX ;
WINN, HR .
SPINE, 1991, 16 (03) :S72-S79
[4]
Reconstruction of the Subaxial Cervical Spine Using Lateral Mass and Facet Screw Instrumentation [J].
Aydogan, Mehmet ;
Enercan, Meric ;
Hamzaoglu, Azmi ;
Alanay, Ahmet .
SPINE, 2012, 37 (05) :E335-E341
[5]
Quantitative anatomic evaluation of cervical lateral mass fixation with a comparison of the Roy-Camille and the Magerl screw techniques [J].
Barrey, C ;
Mertens, P ;
Jund, J ;
Cotton, F ;
Perrin, G .
SPINE, 2005, 30 (06) :E140-E147
[6]
Flexion failure of posterior cervical lateral mass screws - Influence of insertion technique and position [J].
Choueka, J ;
Spivak, JM ;
Kummer, FJ ;
Steger, T .
SPINE, 1996, 21 (04) :462-468
[7]
Ebraheim NA, 1997, J SPINAL DISORD, V10, P308
[8]
The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation [J].
Ebraheim, NA ;
Xu, RM ;
Yeasting, RA .
SPINE, 1996, 21 (11) :1291-1295
[9]
Posterior cervical arthrodesis and stabilization with a lateral mass plate - Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications [J].
Graham, AW ;
Swank, ML ;
Kinard, RE ;
Lowery, GL ;
Dials, BE .
SPINE, 1996, 21 (03) :323-328
[10]
COMPLICATIONS OF POSTERIOR CERVICAL PLATING [J].
HELLER, JG ;
SILCOX, DH ;
SUTTERLIN, CE .
SPINE, 1995, 20 (22) :2442-2448