Revision with plates of humeral nonunions secondary to failed intramedullary nailing

被引:17
作者
Allende, Christian [1 ,2 ]
Paz, Agustin [2 ]
Altube, Gonzalo [2 ]
Boccolini, Hernan [2 ]
Malvarez, Alejandro [2 ]
Allende, Bartolome [1 ]
机构
[1] Sanatorio Allende, Inst Cirugia Reconstruct Miembros, Cordoba, Argentina
[2] Univ Catolica Cordoba, Cordoba, Argentina
关键词
Nonunion; Humerus; Intramedullary nails; Plates; FRACTURES; MANAGEMENT; FIXATION; FAILURE; SHAFT;
D O I
10.1007/s00264-013-2180-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The objective of this study was to evaluate the results achieved after revision with plates of humeral nonunions secondary to failed intramedullary nailing. We retrospectively evaluated 32 patients with humeral nonunions secondary to failed intramedullary nailing, treated by internal fixation with plates between 1998 and 2012. Nonunions were diaphyseal in 19 cases, they were located in the proximal humeral metaphysis in nine cases, and in the distal humeral metaphysis in four cases. There were 11 atrophic nonunions and 21 oligotrophic nonunions. Initial treatment was performed with static locked nails in 12 cases, nails with expansive locking systems in 11 cases, and using thin elastic nails in nine cases. The nails were placed antegrade in 18 cases and retrograde in 14 cases. Time between initial surgery and revision surgery averaged 14.5 months. In seven diaphyseal nonunions, the intramedullary nail was left in-situ. Bone graft was added in 25 cases. Follow-up averaged 35 months. Union was achieved in all cases, after an average of 3.8 months. Disabilities of the Arm, Shoulder and Hand (DASH) score at last follow-up averaged 14 points, and Constant's score averaged 82 points. The analogue scale of pain averaged 0.8 points. Out of seven patients with radial nerve compromise, six recovered completely and one needed tendon transfers. Revision with plates after failed intramedullary humeral nailing achieved union and good predictable objective and subjective results in all cases. Adequate implant selection and meticulous surgical technique are necessary to achieve successful osteosynthesis and bony union.
引用
收藏
页码:899 / 903
页数:5
相关论文
共 34 条
[1]
Allende Christian, 2010, Tech Hand Up Extrem Surg, V14, P241, DOI 10.1097/BTH.0b013e3181f42bd3
[2]
Infected nonunions of long bones of the upper extremity: staged reconstruction using polymethylmethacrylate and bone graft impregnated with antibiotics. [J].
Allende C. ;
Mangupli M. ;
Bagliardelli J. ;
Diaz P. ;
Allende B.T. .
MUSCULOSKELETAL SURGERY, 2009, 93 (3) :137-142
[3]
The use of a new locking 90A° blade plate in the treatment of atrophic proximal humerus nonunions [J].
Allende, Christian ;
Allende, Bartolome T. .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) :1649-1654
[4]
Post-traumatic distal humerus non-union Open reduction and internal fixation: long-term results [J].
Allende, Christian ;
Allende, Bartolome T. .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) :1289-1294
[5]
BILATEROTRICIPITAL APPROACH TO ELBOW - ITS APPLICATION IN OSTEOSYNTHESIS OF SUPRACONDYLAR FRACTURES OF HUMERUS IN CHILDREN [J].
ALONSOLLAMES, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 1972, 43 (06) :479-490
[6]
Anglen Jeffrey O, 2009, Instr Course Lect, V58, P3
[7]
[Anonymous], COCHRANE DATABASE SY
[8]
Bain G., 1992, JBJS Br, P39
[9]
Brinker MR, 2007, J BONE JOINT SURG AM, V89A, P177, DOI 10.2106/JBJS.F.00742
[10]
Antibiotic-impregnated autogenic cancellous bone grafting is an effective and safe method for the management of small infected tibial defects: A comparison study [J].
Chan, YS ;
Ueng, SWN ;
Wang, CJ ;
Lee, SS ;
Chen, CY ;
Shin, CH .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (02) :246-255