关键词
chronic kidney disease; microalbumin; reference material; reference method; urine albumin; MASS-SPECTROMETRY; SERUM-ALBUMIN; STANDARDIZATION; QUANTIFICATION;
D O I
10.1515/cclm-2012-0768
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
100118 [医学信息学]; 100208 [临床检验诊断学];
摘要
Background: Increased urinary excretion of albumin reflects kidney damage and is a recognized risk factor for progression of renal and cardiovascular disease. Considerable inter-method differences have been reported for both albumin and creatinine measurement results, and therefore the albumin-to-creatinine ratio. Measurement accuracy is unknown and there are no independent reference measurement procedures for albumin and no reference materials for either measurand in urine. Methods: The National Kidney Disease Education Program (NKDEP) Laboratory Working Group and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) have initiated joint projects to facilitate standardization of urinary albumin and creatinine measurement. Results: A candidate LC-MS/MS reference measurement procedure for urinary albumin and candidate reference materials for urinary albumin and creatinine has been developed. The status of validations of these reference system components is reported. Conclusions: The development of certified reference materials and reference measurement procedures for urinary albumin will enable standardization of this important measurand.
引用
收藏
页码:981 / 989
页数:9
相关论文
共 12 条
[1]
Baudner S, 1993, THE CERTIFICATION OF
[2]
Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material [J].
Blirup-Jensen, Soren ;
Johnson, A. Myron ;
Larsen, Marianne .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (10) :1470-1479
[3]
Bunk DM, 2012, METHODS MOL BIOL, V828, P29, DOI 10.1007/978-1-61779-445-2_3
[4]
CALCULATION OF PROTEIN EXTINCTION COEFFICIENTS FROM AMINO-ACID SEQUENCE DATA [J].
GILL, SC ;
VONHIPPEL, PH .
ANALYTICAL BIOCHEMISTRY, 1989, 182 (02) :319-326
[5]
Determination of creatinine in urine by tandem mass spectrometry [J].
Husková, R ;
Chrastina, P ;
Adam, T ;
Schneiderka, P .
CLINICA CHIMICA ACTA, 2004, 350 (1-2) :99-106
[6]
Commutability of the ERM-DA470k Reference Material for two assays measuring serum albumin using immunochemical principles [J].
Infusino, Ilenia ;
Braga, Federica ;
Valente, Cristina ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) :1383-1384
[7]
Preparation of highly purified monomeric human serum albumin as secondary reference material for standardization of urinary albumin immunoassays [J].
Itoh, Yoshihisa ;
Ichihara, Kiyoshi ;
Kishi, Kouji ;
Hosogaya, Shigemi ;
Yamada, Toshiyuki .
CLINICA CHIMICA ACTA, 2012, 413 (1-2) :175-181
[8]
Current Issues in Measurement and Reporting of Urinary Albumin Excretion [J].
Miller, W. Greg ;
Bruns, David E. ;
Hortin, Glen L. ;
Sandberg, Sverre ;
Aakre, Kristin M. ;
McQueen, Matthew J. ;
Itoh, Yoshihisa ;
Lieske, John C. ;
Seccombe, David W. ;
Jones, Graham ;
Bunk, David M. ;
Curhan, Gary C. ;
Narva, Andrew S. .
CLINICAL CHEMISTRY, 2009, 55 (01) :24-38
[9]
Quantification of Urinary Albumin by Using Protein Cleavage and LC-MS/MS [J].
Seegmiller, Jesse C. ;
Barnidge, David R. ;
Burns, Bradley E. ;
Larson, Timothy S. ;
Lieske, John C. ;
Kumar, Rajiv .
CLINICAL CHEMISTRY, 2009, 55 (06) :1100-1107
[10]
A liquid chromatography-mass spectrometry method for the quantification of urinary albumin using a novel 15N-isotopically labeled albumin internal standard [J].
Singh, Ravinder ;
Crow, Frank W. ;
Babic, Nikolina ;
Lutz, Ward H. ;
Lieske, John C. ;
Larson, Timothy S. ;
Kumar, Rajiv .
CLINICAL CHEMISTRY, 2007, 53 (03) :540-542