Simultaneous spectrophotometric determination of nitrite nitrate by flow-injection analysis

被引:78
作者
Ahmed, MJ [1 ]
Stalikas, CD [1 ]
TzouwaraKarayanni, SM [1 ]
Karayannis, MI [1 ]
机构
[1] UNIV IOANNINA,DEPT CHEM,ANALYT CHEM LAB,GR-45110 IOANNINA,GREECE
关键词
flow-injection analysis; nitrate determination; nitrite determination; spectrophotometry;
D O I
10.1016/0039-9140(95)01824-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)ethylenediamine dihydrochloride to form a stable purple azo dye, the absorbance of which is measured at 535 nm. Nitrate is reduced on-line to nitrite in a copper-coated cadmium column which is then treated with azo dye reagent and the absorbance due to the sum of nitrite and nitrate is measured; nitrate is determined from the difference in absorbance values. A copper column incorporated into the reaction manifold before the copperised cadmium column not only improves the long-term accuracy, but also extends the life time of the copperised cadmium column. Various analytical parameters, such as effect of acidity (pH), flow rate, sample size, dispersion coefficient, time, temperature, reagent concentration and interfering species, were studied. The calibration graphs were rectilinear for 0.1-3.5 mu g ml(-1) of NO3- and 10 ng ml(-1)-2.2 mu g ml(-1) of NO2-. The method is successfully applied to some food samples (meat, flour and cheese), environmental waters (inland and surface), beer and soil samples. Up to 30 samples can be analysed per hour with a relative precision of approximate to 0.1-2%.
引用
收藏
页码:1009 / 1018
页数:10
相关论文
共 19 条
[2]   CONFIGURATION WITH INTERNALLY COUPLED VALVES TO OVERCOME SHORTCOMINGS IN THE SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY FLOW-INJECTION ANALYSIS [J].
BERMUDEZ, B ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1988, 35 (10) :810-812
[3]   THE EVALUATION AND COMPARISON OF ION CHROMATOGRAPHY, SEGMENTED FLOW-ANALYSIS AND FLOW-INJECTION ANALYSIS FOR THE DETERMINATION ON NITRATE IN NATURAL SURFACE WATERS [J].
BURKE, EM ;
SUAREZ, FX ;
HILLMAN, DC ;
HEITHMAR, EM .
WATER RESEARCH, 1989, 23 (04) :519-521
[4]   FLOW-INJECTION DETERMINATION OF INORGANIC FORMS OF NITROGEN BY GAS-DIFFUSION AND CONDUCTIMETRY [J].
DEFARIA, LC ;
PASQUINI, C .
ANALYTICA CHIMICA ACTA, 1991, 245 (02) :183-190
[5]   SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS [J].
GINE, MF ;
BERGAMIN, H ;
ZAGATTO, EAG ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :191-197
[6]  
HELRICH K, 1990, OFFICIAL MTHODS ANAL
[7]   SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF NITRITE AND NITRATE IN A FLOW-INJECTION SYSTEM [J].
KOJLO, A ;
GORODKIEWICZ, E .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :283-287
[8]   AUTOMATED-DETERMINATION OF NITRATE IN WATERS WITH A REDUCTION COLUMN IN A MICROCOMPUTER-BASED STOPPED-FLOW SAMPLE PROCESSING SYSTEM [J].
KOUPPARIS, MA ;
WALCZAK, KM ;
MALMSTADT, HV .
ANALYTICA CHIMICA ACTA, 1982, 142 (OCT) :119-127
[9]   FLOW-INJECTION DETERMINATION OF NITRATE IN VEGETABLES USING A TUBULAR POTENTIOMETRIC DETECTOR [J].
LIMA, JLFC ;
RANGEL, AOSS ;
SOUTO, MRS .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (03) :704-707
[10]   AUTOMATIC SYSTEM FOR SIMULTANEOUS DETERMINATION OF NITRATES AND NITRITES IN WATERS [J].
MAIMO, J ;
CLADERA, A ;
MAS, F ;
FORTEZA, R ;
ESTELA, JM ;
CERDA, V .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1989, 35 (03) :161-167