How accurate is visual assessment of synchronicity in myocardial motion?: An in vitro study with computer-simulated regional delay in myocardial motion:: Clinical implications for rest and stress echocardiography studies

被引:94
作者
Kvitting, JPE
Wigström, L
Strotmann, JM
Sutherland, GR [1 ]
机构
[1] Linkoping Univ Hosp, Dept Cardiol, Linkoping Heart Ctr, S-58185 Linkoping, Sweden
[2] Linkoping Univ Hosp, Dept Clin Physiol, Linkoping Heart Ctr, S-58185 Linkoping, Sweden
关键词
D O I
10.1016/S0894-7317(99)70019-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Asynchronicity ih. echocardiographic images is normally assessed visually. No prior quantitative studies have determined the limitations of this approach. To quantify visual recognition of myocardial asynchronicity in echocardiographic images, computer-simulated delay phantom loops were generated from a 3.3 MHz digital image data from a normal left ventricular short-axis heart cycle acquired at 55 frames per second. Slit expect observers visually assessed 30 abnormal and 3 normal loops with differing computer-induced delay patterns on 3 occasions and in this optimally simulated environment could recognize only single delays of 89 ms or more, This was improved to 71 ms or more by use of side-by-side (normal versus abnormal) comparative review. Thus visual assessment of clinically important regional delay in rest or stress echo images is limited.
引用
收藏
页码:698 / 705
页数:8
相关论文
共 11 条
  • [1] Reproducibility of digital exercise echocardiography
    Ali, SM
    Egeblad, H
    Saunamaki, K
    Carstensen, S
    SteensgardHansen, F
    Haunso, S
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 (11) : 1510 - 1519
  • [2] Bijnens B., 1998, European Heart Journal, V19, P209
  • [3] Doppler tissue imaging quantitates regional wall motion during myocardial ischemia and reperfusion
    Derumeaux, G
    Ovize, M
    Loufoua, J
    André-Fouet, X
    Minaire, Y
    Cribier, A
    Letac, B
    [J]. CIRCULATION, 1998, 97 (19) : 1970 - 1977
  • [4] LEFT-VENTRICULAR ASYNCHRONY - AN INDICATOR OF REGIONAL MYOCARDIAL DYSFUNCTION
    EHRING, T
    HEUSCH, G
    [J]. AMERICAN HEART JOURNAL, 1990, 120 (05) : 1047 - 1057
  • [5] GUTH BD, 1993, CIRCULATION, V87, P35
  • [6] Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms
    Hoffmann, R
    Lethen, H
    Marwick, T
    Arnese, M
    Fioretti, P
    Pingitore, A
    Picano, E
    Buck, T
    Erbel, R
    Flachskampf, FA
    Hanrath, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) : 330 - 336
  • [7] Temporal factors in visual perception: A differential approach
    Jones, MB
    Kennedy, RS
    [J]. PERCEPTUAL AND MOTOR SKILLS, 1995, 81 (03) : 859 - 867
  • [8] Echocardiographic quantification of regional left ventricular wall motion with color kinesis
    Lang, RM
    Vignon, P
    Weinert, L
    Bednarz, J
    Korcarz, C
    Sandelski, J
    Koch, R
    Prater, D
    MorAvi, V
    [J]. CIRCULATION, 1996, 93 (10) : 1877 - 1885
  • [9] FLICKER FUSION PHENOMENA
    LEVINSON, JZ
    [J]. SCIENCE, 1968, 160 (3823) : 21 - &
  • [10] FOVEAL FLICKER-FUSION FREQUENCIES - A SIMPLE, NEW APPARATUS (4F)
    NEETENS, A
    VANDENENDE, P
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (04) : 358 - 361