Magnetic nano-adsorbent integrated with lab-on-valve system for trace analysis of multiple heavy metals

被引:60
作者
Lee, Pei-Ling [2 ]
Sun, Yuh-Chang [2 ]
Ling, Yong-Chien [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30013, Taiwan
[2] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
关键词
PLASMA-MASS SPECTROMETRY; CHELATION ION CHROMATOGRAPHY; FLOW-INJECTION ANALYSIS; ICP-MS; SEQUENTIAL INJECTION; AMBERLITE XAD-4; ONLINE PRECONCENTRATION; RENEWABLE MICROCOLUMN; SEPARATION; RESIN;
D O I
10.1039/b814164a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel system for trace analysis of multiple heavy metals was developed wherein we have integrated a magnetic nano-adsorbent with a lab-on-valve system and coupled this to an inductively coupled plasma mass spectrometer. The magnetic nano-adsorbent was prepared by surface modification of iron-based magnetic nanoparticles with polyacrylic acid (MNPs-PAA). The MNPs-PAA possessing the superparamagnetic nature of MNPs could be controllably immobilized in PTFE tubing by an external magnetic force. The high surface density of PAA (3.30 x 10(11) molecules cm(-2)) on MNPs-PAA significantly reduced the amounts of adsorbent needed for adsorption of heavy metals (Mn2+, Co2+, Cu2+, Zn2+, and Pb2+). A detection limit of 0.04-0.06 mu g L-1 (except 0.6 mu g L-1 for Cu2+ and Zn2+), a precision smaller than 4% (RSD, n = 3), and a linear range of 0.5-50 mu g L-1 were obtained by directly injecting an aliquot of 20 mu L fortified standard solution analyzed at 5 min per sample. The accuracy was evaluated by analyzing certified reference materials of SRM 2670a (trace elements in urine, low level) and CASS-2 (nearshore seawater reference material for trace metals). Good agreement between the measured and certified values demonstrated that the system is useful for trace analysis of multiple heavy metals in environmental and biological aqueous samples. The potential of integrating functionalized nano-materials to improve the performance of existing analytical systems as an alternative approach to green analytical chemistry is foreseen.
引用
收藏
页码:320 / 327
页数:8
相关论文
共 36 条
[1]   Ionic strength, pH and temperature effects upon selectivity for transition and heavy metal ions when using chelation ion chromatography with an iminodiacetic acid bonded silica gel column and simple inorganic eluents [J].
Bashir, W ;
Paull, B .
JOURNAL OF CHROMATOGRAPHY A, 2002, 942 (1-2) :73-82
[2]   Inductively coupled plasma mass spectrometry [J].
Beauchemin, D .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2873-2893
[3]   Atomic spectroscopy [J].
Bings, Nicolas H. ;
Bogaerts, Annemie ;
Broekaert, Jose A. C. .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3917-3945
[4]   Use of an o-aminobenzoic acid-functionalized XAD-4 copolymer resin for the separation and preconcentration of heavy metal(II) ions [J].
Çekiç, SD ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :15-24
[5]   Application of the SAXS method and viscometry for determination of the thickness of adsorbed polymer layers at the ZrO2-polymer solution interface [J].
Chibowski, S ;
Wisniewska, M ;
Marczewski, AW ;
Pikus, S .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2003, 267 (01) :1-8
[6]   In vivo monitoring of multiple trace metals on the brain extracellular fluid of anesthetized rats by microdialysis-membrane Desalter-ICPMS [J].
Chung, Y. T. ;
Ling, Y. C. ;
Yang, C. S. ;
Sun, Y. C. ;
Lee, P. L. ;
Lin, C. Y. ;
Hong, C. C. ;
Yang, M. H. .
ANALYTICAL CHEMISTRY, 2007, 79 (23) :8900-8910
[7]  
DAWSON RMC, 1998, DATA BIOCH RES
[8]   Development of column-pretreatment chelating resins for matrix elimination/multi-element determination by inductively coupled plasma-mass spectrometry [J].
Gao, YH ;
Oshita, K ;
Lee, KH ;
Oshima, M ;
Motomizu, S .
ANALYST, 2002, 127 (12) :1713-1719
[9]   Adsorption mechanism in reversed-phase liquid chromatography -: Effect of the surface coverage of a monomeric C18-silica stationary phase [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1115 (1-2) :142-163
[10]   Biofunctional magnetic nanoparticles for protein separation and pathogen detection [J].
Gu, HW ;
Xu, KM ;
Xu, CJ ;
Xu, B .
CHEMICAL COMMUNICATIONS, 2006, (09) :941-949