Indoor air quality investigation at air-conditioned and non-airconditioned markets in Hong Kong

被引:52
作者
Guo, H [1 ]
Lee, SC [1 ]
Chan, LY [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Res Ctr Urban Environm Technol & Management, Kowloon, Hong Kong, Peoples R China
关键词
market; air conditioned; indoor air quality; Hong Kong;
D O I
10.1016/j.scitotenv.2003.09.031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM10 (particulate matters with aerodynamic diameter less than 10 mum), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO2) and sulfur dioxide (SO2). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM10, TBC, CO and NO2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM10 and TBC. The elevated PM10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM10 concentration at poultry stalls was higher than the HKIAQO standard of 180 mug/m(3), and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m(3), which was above the HKIAQO standard of 1000 CFU/m(3). The bacteria levels at other three stalls were all below the HKIAQO standard. Statistical analysis indicated that there were no significant differences among the four stalls for CO, NO, and SO,. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 18 条
[1]  
BACK SO, 1997, ATMOS ENVIRON, V31, P529
[2]  
Batterman A.S., 1995, RES HVACR, V1, P61, DOI DOI 10.1080/10789669.1995.10391309
[3]  
BURGE HA, 1992, DESICCANT COOLING DE, P13
[4]  
*HKEPD, 2002, MIL HONG KONG ENV PR
[5]  
*HKEPD, 1999, GUID NOT MAN IND AIR
[6]  
*HKEPD, 2001, IND AIR QUAL
[7]   Indoor/outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations [J].
Jones, NC ;
Thornton, CA ;
Mark, D ;
Harrison, RM .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (16) :2603-2612
[8]   Characteristics of bioaerosol profile in office buildings in Hong Kong [J].
Law, AKY ;
Chau, CK ;
Chan, GYS .
BUILDING AND ENVIRONMENT, 2001, 36 (04) :527-541
[9]   Indoor and outdoor air quality investigation at schools in Hong Kong [J].
Lee, SC ;
Chang, M .
CHEMOSPHERE, 2000, 41 (1-2) :109-113
[10]   Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong [J].
Lee, SC ;
Guo, H ;
Li, WM ;
Chan, LY .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (12) :1929-1940