Texture analysis of sonographic features of the parotid gland in sjogren's syndrome

被引:70
作者
Ariji, Y [1 ]
Ohki, M [1 ]
Eguchi, K [1 ]
Izumi, M [1 ]
Arji, E [1 ]
Mizokami, A [1 ]
Nagataki, S [1 ]
Nakamura, T [1 ]
机构
[1] NAGASAKI UNIV,SCH MED,DEPT INTERNAL MED 1,NAGASAKI 852,JAPAN
关键词
D O I
10.2214/ajr.166.4.8610577
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. The purpose of this study was to develop a method for quantitative analysis of the sonographic features of parotid glands as a noninvasive tool for the diagnosis of Sjogren's syndrome. SUBJECTS AND METHODS. Sonographic texture analyses were performed on the parotid glands of 44 patients with Sjogren's syndrome, 83 healthy volunteers, and 17 patients with chronic parotitis, using a fast Fourier transform program. RESULTS. Texture analysis of sonographic studies of the parotid gland using a Fourier transform showed that the sum of the normalized radial power spectrum in the low-spatial-frequency region (S value) of the parotid gland was significantly higher (p <.0001) in the patients with definite Sjogren's syndrome [6.70 +/- 2.13 (x10(5))] than in the 72 age-matched normal Volunteers [3.25 +/- 1.08 (x10(5))]. However, patients with probable Sjogren's syndrome showed S values [3.92 +/- 1.88 (x10(5))] similar to those of the controls. On the other hand, SDs of the echo levels in the parotid gland showed significantly greater (p <.0001) values in patients with definite (4.63 +/- 1.07) and probable (4.53 +/- 1.47) Sjogren's syndrome than in the normal controls (3.30 +/- 0.76). Discriminant analysis showed that a combination of these two distinctive values increased diagnostic accuracy to 96.9%. Furthermore, S values and SDs correlated well with the qualitative grading of sonographic features and with the gradings of sialography. CONCLUSION. The system we describe for texture analysis of sonographic images is useful in the diagnosis of Sjogren's syndrome.
引用
收藏
页码:935 / 941
页数:7
相关论文
共 14 条
[1]
COMPUTER-AIDED DETECTION OF DIFFUSE LIVER-DISEASE IN ULTRASOUND IMAGES [J].
ABE, C ;
KAHN, CE ;
DOI, K ;
KATSURAGAWA, S .
INVESTIGATIVE RADIOLOGY, 1992, 27 (01) :71-77
[2]
PAROTID-GLAND - ULTRASOUND FINDINGS IN SJOGREN SYNDROME - WORK IN PROGRESS [J].
BRADUS, RJ ;
HYBARGER, P ;
GOODING, GAW .
RADIOLOGY, 1988, 169 (03) :749-751
[3]
FEASIBILITY OF IDENTIFYING AMYLOID AND HYPERTROPHIC CARDIOMYOPATHY WITH THE USE OF COMPUTERIZED QUANTITATIVE TEXTURE ANALYSIS OF CLINICAL ECHOCARDIOGRAPHIC DATA [J].
CHANDRASEKARAN, K ;
AYLWARD, PE ;
FLEAGLE, SR ;
BURNS, TL ;
SEWARD, JB ;
TAJIK, AJ ;
COLLINS, SM ;
SKORTON, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (04) :832-840
[4]
SJOGRENS-SYNDROME - PROPOSED CRITERIA FOR CLASSIFICATION [J].
FOX, RI ;
ROBINSON, CA ;
CURD, JG ;
KOZIN, F ;
HOWELL, FV .
ARTHRITIS AND RHEUMATISM, 1986, 29 (05) :577-585
[5]
IMPROVING THE DISTINCTION BETWEEN BENIGN AND MALIGNANT BREAST-LESIONS - THE VALUE OF SONOGRAPHIC TEXTURE ANALYSIS [J].
GARRA, BS ;
KRASNER, BH ;
HORII, SC ;
ASCHER, S ;
MUN, SK ;
ZEMAN, RK .
ULTRASONIC IMAGING, 1993, 15 (04) :267-285
[6]
HISTOPATHOLOGY OF SJOGRENS SYNDROME IN LABIAL SALIVARY-GLAND BIOPSIES [J].
GREENSPAN, JS ;
DANIELS, TE ;
TALAL, N ;
SYLVESTER, RA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1974, 37 (02) :217-229
[7]
ITOH K, 1985, J CLIN ULTRASOUND, V13, P449, DOI 10.1002/jcu.1870130703
[8]
SALIVARY-GLAND ECHOGRAPHY IN PATIENTS WITH SJOGRENS-SYNDROME [J].
KAWAMURA, H ;
TANIGUCHI, N ;
ITOH, K ;
KANO, S .
ARTHRITIS AND RHEUMATISM, 1990, 33 (04) :505-510
[9]
USE OF TEXTURE ANALYSIS TO DISCRIMINATE BETWEEN NORMAL LIVERS AND LIVERS WITH STEATOSIS [J].
KHOO, BCC ;
MCQUEEN, MPC ;
SANDLE, WJ .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (06) :489-494
[10]
COMPUTER-ANALYSIS OF ECHOGRAPHIC TEXTURES IN HASHIMOTO DISEASE OF THE THYROID [J].
MAILLOUX, G ;
BERTRAND, M ;
STAMPFLER, R ;
ETHIER, S .
JOURNAL OF CLINICAL ULTRASOUND, 1986, 14 (07) :521-527