Evanescent field in surface plasmon resonance and surface plasmon field-enhanced fluorescence spectroscopies

被引:86
作者
Ekgasit, S [1 ]
Thammacharoen, C
Yu, F
Knoll, W
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, Sensor Res Unit, Bangkok 10330, Thailand
[2] Max Planck Inst Polymer Res, D-55128 Mainz, Germany
关键词
D O I
10.1021/ac035326f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The highly sensitive nature of surface plasmon resonance (SPR) spectroscopy and surface plasmon field-enhanced fluorescence spectroscopy (SPFS) are governed by the strong surface plasmon resonance-generated evanescent field at the metal/dielectric interface. The greatest evanescent field amplitude at the interface and the maximum attenuation of the reflectance are observed when a nonabsorbing dielectric is employed. An absorbing dielectric decreases the evanescent field enhancement at the interface. The SPR curve of an absorbing dielectric is characterized by a greater reflectance minimum and a broader curve, as compared to those of the nonabsorbing dielectric with the same refractive index. For a weakly absorbing dielectric, such as nanometer-thick surface-confined fluorophores, the absorption is too small to induce a significant change in the SPR curve. However, the presence of a minute amount of the fluorophore can be detected by the highly sensitive SPFS. The angle with the maximum fluorescence intensity of an SPFS curve is always smaller than the resonance angle of the corresponding SPR curve. This discrepancy is due to the differences of evanescent field distributions and their decay characteristics within the metal film and the dielectric medium. The fluorescence intensity in an SPFS curve can be expressed in terms of the evanescent field amplitude. Excellent correlations between the experimentally measured fluorescence intensities and the evanescent field amplitudes are observed.
引用
收藏
页码:2210 / 2219
页数:10
相关论文
共 26 条
[1]   Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor [J].
Anderson, GP ;
Nerurkar, NL .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 271 (1-2) :17-24
[2]   SENSITIVITY ENHANCEMENT OF OPTICAL IMMUNOSENSORS BY THE USE OF A SURFACE-PLASMON RESONANCE FLUOROIMMUNOASSAY [J].
ATTRIDGE, JW ;
DANIELS, PB ;
DEACON, JK ;
ROBINSON, GA ;
DAVIDSON, GP .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) :201-214
[3]   Properties of poly(3,4-ethylenedioxythiophene) ultrathin films detected by in situ electrochemical-surface plasmon field-enhanced photoluminescence spectroscopy [J].
Baba, A ;
Knoll, W .
JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (31) :7733-7738
[4]  
Barnes WL, 1998, J MOD OPTIC, V45, P661, DOI 10.1080/09500349808230614
[5]   Spectroscopic study and evaluation of red-absorbing fluorescent dyes [J].
Buschmann, V ;
Weston, KD ;
Sauer, M .
BIOCONJUGATE CHEMISTRY, 2003, 14 (01) :195-204
[6]   Technique for an accurate estimation of the mean square electric field in ATR FT-IR spectroscopy [J].
Ekgasit, S .
APPLIED SPECTROSCOPY, 1998, 52 (05) :773-776
[7]   ATR spectral intensity: What is the upper limit of weak absorption? [J].
Ekgasit, S .
APPLIED SPECTROSCOPY, 2000, 54 (05) :756-758
[8]   Optical contact in ATR/FT-IR spectroscopy [J].
Ekgasit, S ;
Padermshoke, A .
APPLIED SPECTROSCOPY, 2001, 55 (10) :1352-1359
[9]   Surface plasmon resonance for real time in situ analysis of protein adsorption to polymer surfaces [J].
Green, RJ ;
Davies, J ;
Davies, MC ;
Roberts, CJ ;
Tendler, SJB .
BIOMATERIALS, 1997, 18 (05) :405-413