Stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry for trace analysis of benzophenone and its derivatives in water sample

被引:49
作者
Kawaguchi, M
Ito, R
Endo, N
Sakui, N
Okanouchi, N
Saito, K
Sato, N
Shiozaki, T
Nakazawa, H
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, Tokyo 1428501, Japan
[2] Yokogawa Analyt Syst Inc, Tokyo 1920033, Japan
[3] Japan Environm Sanitat Ctr, Dept Environm Sci, Div Environm Sci, Kawasaki, Kanagawa 2100828, Japan
关键词
benzophenone; water sample; stir bar sorptive extraction (SBSE); thermal desorption (TD); gas chromatography-mass spectrometry (GC-MS);
D O I
10.1016/j.aca.2005.08.087
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive method called stir bar sorptive extraction (SBSE) and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of benzophenone (BP) and its derivatives, 2-hydroxy-4-methoxybenzophenone (BP-3) and 2-hydroxy-4-methoxy-4'-methylbenzophenone (BP-10), in river water samples, is described. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 10 ml water sample and stirring is carried out for 120 min at room temperature (25 degrees C) in a vial. Then, the PDMS stir bar is subjected to TD-GC-MS. The detection limit is 0.5-1 pg ml(-1) for BPs. The method shows good linearity and the correlation coefficients are higher than 0.997 for all the analytes. The average recoveries of the BPs are equal to or higher than 98.5% (R.S.D.: 1.5-5.1%). This simple, accurate, sensitive and selective analytical method may be used in the determination of trace amounts of BPs in river water samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 30 条
[1]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[2]  
2-4
[3]   Analysis of off-flavors in the aquatic environment by stir bar sorptive extraction-thermal desorption-capillary GC/MS/olfactometry [J].
Benanou, D ;
Acobas, F ;
de Roubin, MR ;
Sandra, FDP .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (01) :69-77
[4]   Impact of water/PDMS phase ratio, volume of PDMS, and sampling time on Stir Bar Sorptive Extraction (SBSE) recovery of some pesticides with different KO/W [J].
Bicchi, C ;
Cordero, C ;
Rubiolo, P ;
Sandra, P .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (18) :1650-1656
[5]  
Castillo M, 1997, J MASS SPECTROM, V32, P1100, DOI 10.1002/(SICI)1096-9888(199711)32:10<1100::AID-JMS564>3.3.CO
[6]  
2-1
[7]   Determination of the UV filters worldwide authorised in sunscreens by high-performance liquid chromatography -: Use of cyclodextrins as mobile phase modifier [J].
Chisvert, A ;
Pascual-Martí, MC ;
Salvador, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (02) :207-215
[8]   Determination of benzophenone-3 and metabolites in water and human urine by solid-phase microextraction and quadrupole ion trap GC-MS [J].
Felix, T ;
Hall, BJ ;
Brodbelt, JS .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :195-203
[9]   Determination of residues of UV filters in natural waters by solid-phase extraction coupled to liquid chromatography-photodiode array detection and gas chromatography-mass spectrometry [J].
Giokas, DL ;
Sakkas, VA ;
Albanis, TA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1026 (1-2) :289-293
[10]   Stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry for measurement of phenolic xenoestrogens in human urine samples [J].
Kawaguchi, M ;
Sakui, N ;
Okanouchi, N ;
Ito, R ;
Saito, K ;
Izumi, SI ;
Makino, T ;
Nakazawa, H .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01) :49-57