Compact optical diagnostic device for isothermal nucleic acids amplification

被引:49
作者
Lee, Szu-Yuan [2 ,3 ,4 ]
Huang, Jhen-Gang [2 ]
Chuang, Tsung-Liang [2 ]
Sheu, Jin-Chuan [5 ]
Chuang, Yi-Kuang [6 ]
Holl, Mark [7 ,8 ,9 ]
Meldrum, Deirdre R. [7 ,8 ,9 ]
Lee, Chun-Nan [3 ]
Lin, Chii-Wann [1 ,2 ,10 ,11 ]
机构
[1] Natl Taiwan Univ, Coll Med, Inst Biomed Engn, Med Microsensor & Syst Lab, Taipei 106, Taiwan
[2] Natl Taiwan Univ, Coll Engn, Taipei 106, Taiwan
[3] Natl Taiwan Univ, Dept Clin Lab Sci & Med Biotechnol, Taipei 106, Taiwan
[4] Mil Taichung Gen Hosp, Dept Lab Examinat, Taichung, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Lab Med, Taipei, Taiwan
[7] Arizona State Univ, Ira A Fulton Sch Engn, Phoenix, AZ USA
[8] Arizona State Univ, Dept Elect Engn, Phoenix, AZ USA
[9] Arizona State Univ, Biodesign Inst, Ctr Ecogenom, Phoenix, AZ USA
[10] Natl Taiwan Univ, Inst Elect Engn, Taipei 106, Taiwan
[11] Natl Taiwan Univ, Ctr Nano Sci & Technol, Taipei 106, Taiwan
关键词
LAMP; isothermal; diagnostic device; hepatitis B virus;
D O I
10.1016/j.snb.2008.03.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We recently reported the successful use of the loop-mediated isothermal amplification (LAMP) reaction for hepatitis B virus (HBV) DNA amplification and its optimal primer design method. In this study, we report the development of an integrated isothermal device for both amplification and detection of targeted HBV DNA. It has two major components, a disposable polymethyl methacrylate (PMMA) micro-reactor and a temperature-regulated optical detection unit (base apparatus) for real-time monitoring of the turbidity changes due to the precipitation of DNA amplification by-product, magnesium pyrophosphate. We have established a correlation curve (R-2 = 0.99) between the concentration of pyrophosphate ions and the level of turbidity by using a simulated chemical reaction to evaluate the characteristics of our device. For the applications of rapid pathogens detection, we also have established a standard curve (R-2 = 0.96) by using LAMP reaction with a standard template in our device. Moreover, we also have successfully used the device on seven clinical serum specimens where HBV DNA levels have been confirmed by real-time PCR. The result indicates that different amounts of HBV DNA can be successfully detected by using this device within 1 h. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:493 / 501
页数:9
相关论文
共 26 条
  • [1] NUCLEIC-ACID SEQUENCE-BASED AMPLIFICATION
    COMPTON, J
    [J]. NATURE, 1991, 350 (6313) : 91 - 92
  • [2] A miniaturized germanium-doped silicon dioxide-based surface plasmon resonance waveguide sensor for immunoassay detection
    Huang, Jhen-Gang
    Lee, Chen-Lung
    Lin, Hsueh-Min
    Chuang, Tsung-Liang
    Wang, Way-Seen
    Juang, Rong-Huey
    Wang, Ching-Ho
    Lee, Chih Kung
    Lin, Shi-Ming
    Lin, Chii-Wann
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 22 (04) : 519 - 525
  • [3] Predicting cirrhosis risk based on the level of circulating hepatitis B viral load
    Iloeje, UH
    Yang, HI
    Su, J
    Jen, CL
    You, SL
    Chen, CJ
    [J]. GASTROENTEROLOGY, 2006, 130 (03) : 678 - 686
  • [4] Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection
    Imai, Masaki
    Ninomiya, Ai
    Minekawa, Harumi
    Notomi, Tsugunori
    Ishizaki, Toru
    Tashiro, Masato
    Odagiri, Takato
    [J]. VACCINE, 2006, 24 (44-46) : 6679 - 6682
  • [5] Rapid detection and typing of influenza A and B by loop-mediated isothermal amplification: Comparison with immunochromatography and virus isolation
    Ito, Masahiro
    Watanabe, Masahiro
    Nakagawa, Naoko
    Ihara, Toshiaki
    Okuno, Yoshinobu
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2006, 135 (02) : 272 - 275
  • [6] Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples
    Iwamoto, T
    Sonobe, T
    Hayashi, K
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) : 2616 - 2622
  • [7] Rapid detection of Epstein-Barr virus DNA by loop-mediated isothermal amplification method
    Iwata, Seiko
    Shibata, Yukiko
    Kawada, Jun-ichi
    Hara, Shinya
    Nishiyama, Yukihiro
    Morishima, Tsuneo
    Ihira, Masaru
    Yoshikawa, Tetsushi
    Asano, Yoshizo
    Kimura, Hiroshi
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2006, 37 (02) : 128 - 133
  • [8] Sensitive and rapid detection of herpes simplex virus and varicella-zoster virus DNA by loop-mediated isothermal amplification
    Kaneko, H
    Iida, T
    Aoki, K
    Ohno, S
    Suzutani, T
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (07) : 3290 - 3296
  • [10] Correlation of HBV DNA levels in serum and liver of chronic hepatitis B patients with cirrhosis
    Lee, CZ
    Huang, GT
    Yang, PM
    Sheu, JC
    Lai, MY
    Chen, DS
    [J]. LIVER, 2002, 22 (02): : 130 - 135