Direct-conversion X-ray imaging detectors for medical, non-destructive testing (NDT), and other applications

被引:5
作者
Lee, DLY [1 ]
Golden, KP [1 ]
Yorker, JG [1 ]
Rodricks, BG [1 ]
Cheung, LK [1 ]
Jeromin, LS [1 ]
机构
[1] Direct Radiog Corp, Hologic Co, Newark, DE 19702 USA
来源
PENETRATING RADIATION SYSTEMS AND APPLICATIONS III | 2001年 / 4508卷
关键词
direct radiography; direct conversion; digital radiography; medical imaging; X-ray detection; selenium; photo conductor; NDT; DQE; MTF;
D O I
10.1117/12.450782
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Direct conversion of x-ray energy into electrical charge has been extensively developed into imaging products in the past few years. Applications include general radiography, mammography, x-ray crystallography, portal imaging, and non-destructive testing. Direct methods avoid intermediate conversion of x-rays into light prior to generating a measurable electrical charge. This eliminates light scattering effects on image sharpness, allowing detectors to be designed to the limit of the theoretical modulation transfer function for a discrete-pixel sensor. Working exposure range can be customized by adjusting bias and thickness of sensor layers in coordination with readout-elcetronics specifications. Mat-Lire amorphous selenium technology and recent progress on higli-quality Thin-Film Transistor (TFT) arrays for computer displays have allowed development of practical large-area high-resolution flat-panel x-ray imaging systems. A variety of design optimizations enable direct-conversion technology to satisfy a wide range of applications.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 25 条
[1]  
CHACKO AK, 1999, MED IMAGING JUL
[2]   New CsI/a-Si 17" x 17" X-ray flat panel detector provides superior detectivity and immediate direct digital output for General Radiography systems [J].
Chaussat, C ;
Chabbal, J ;
Ducourant, T ;
Spinnler, V ;
Vieux, G ;
Neyret, R .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :45-56
[3]   Direct digital mammography image acquisition [J].
Cowen, AR ;
Parkin, GJS ;
Hawkridge, P .
EUROPEAN RADIOLOGY, 1997, 7 (06) :918-930
[4]  
DECKER P, 2000, GERM AUSTR SOC RAD O
[5]  
DENBOER W, 1998, SPIE, V3336
[6]  
EBASHI S, 1991, HDB SYNCHROTRON RAD, V4
[7]  
GINGOLD E, 2000, SPIE, V3977
[8]  
GREENE RE, 1992, COMPUTED RADIOGRAPHY
[9]   SURVEY OF TWO-DIMENSIONAL ELECTRO-OPTICAL X-RAY-DETECTORS [J].
GRUNER, SM ;
MILCH, JR ;
REYNOLDS, GT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2) :287-297
[10]  
JEROMIN LS, 1997, SID, V27, P91