Comparison of the Updated 2011 Appropriate Use Criteria for Echocardiography to the Original Criteria for Transthoracic, Transesophageal, and Stress Echocardiography

被引:43
作者
Mansour, Ibrahim N. [1 ]
Razi, Rabia R. [1 ]
Bhave, Nicole M. [1 ]
Ward, R. Parker [1 ]
机构
[1] Univ Chicago, Med Ctr, Cardiol Sect, Noninvas Imaging Labs,Dept Med, Chicago, IL 60637 USA
关键词
Appropriate use criteria; Transthoracic echocardiography; Transesophageal echocardiography; Stress echocardiography; Utilization; CARDIOLOGY FOUNDATION/AMERICAN SOCIETY; OF-CARDIOLOGY; CLINICAL-APPLICATION; RECOMMENDATIONS;
D O I
10.1016/j.echo.2012.08.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to compare appropriateness designations as determined by the updated 2011 appropriate use criteria (AUC) for echocardiography with prior versions of the AUC for transthoracic echocardiographic (TTE) imaging, transesophageal echocardiographic (TEE) imaging, and stress echocardiographic (SE) imaging. An additional goal was to define relationships between appropriateness determinations and echocardiographic findings for each modality. Methods: Previously published data sets of TTE, TEE, and SE studies were reclassified according to the 2011 AUC, and indication representation, appropriateness designations, and echocardiographic findings were compared with prior classifications according to the 2007 AUC for TTE and TEE imaging and the 2008 AUC for SE imaging. Results: Overall, 2,247 echocardiographic studies were analyzed. The 2011 AUC addressed the vast majority of studies (98%), a marked increase compared with prior versions of the AUC (89%) (P < .001). An increase in addressed studies was present in each echocardiographic modality (TTE imaging: n = 1,525, 98% vs 89%, P < .001; TEE imaging: n = 405, 99.7% vs 91%, P < .01; SE imaging: n = 289, 97% vs 88%, P < .01). Among all echocardiographic procedures, the 2011 AUC found a lower frequency of appropriate studies compared with prior AUC (82% vs 88%, P < .01), primarily because of new uncertain indications for TTE imaging. The frequency of inappropriate echocardiographic studies was unchanged (11%). Among all echocardiographic procedures, the 2011 AUC found appropriate studies to have more new abnormal echocardiographic findings compared with inappropriate studies (45% vs 13%, P <. 001). Interestingly, 2011 AUC inappropriate TTE studies had fewer major new echocardiographic abnormalities than 2007 AUC inappropriate TTE studies (9% vs 17%, P = .04). Conclusions: The updated 2011 AUC for echocardiography encompass the vast majority of echocardiographic procedures in a university hospital practice, filling virtually all of the gaps identified in prior versions of the AUC for TTE, TEE, and SE imaging. The 2011 AUC also reasonably stratify the likelihood of finding an echocardiographic abnormality, demonstrating improvement compared with the prior AUC. (J Am Soc Echocardiogr 2012;25:1153-61.)
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 24 条
[1]   Application of the Appropriateness Criteria for Echocardiography in an Academic Medical Center [J].
Aggarwal, Niti R. ;
Wuthiwaropas, Punsak ;
Karon, Barry L. ;
Miller, Fletcher A. ;
Pellikka, Patricia A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (03) :267-274
[2]  
Alqarqaz M, INT J CARDI IN PRESS
[3]   Stress echocardiography: Recommendations for performance and interpretation of stress echocardiography [J].
Armstrong, WF ;
Pellikka, PA ;
Ryan, T ;
Crouse, L ;
Zoghbi, WA .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (01) :97-104
[4]   Application of 2011 American College of Cardiology Foundation/American Society of Echocardiography Appropriateness Use Criteria in Hospitalized Patients Referred for Transthoracic Echocardiography in a Community Setting [J].
Ballo, Piercarlo ;
Bandini, Fabrizio ;
Capecchi, Irene ;
Chiodi, Leandro ;
Ferro, Giuseppe ;
Fortini, Alberto ;
Giuliani, Gabriele ;
Landini, Giancarlo ;
Laureano, Raffaele ;
Milli, Massimo ;
Nenci, Gabriele ;
Pizzarelli, Francesco ;
Santoro, Giovanni Maria ;
Vannelli, Pasquale ;
Cappelletti, Carlo ;
Zuppiroli, Alfredo .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (06) :589-598
[5]   ACCF/ASE/ACEP/AHA/ASNC/SCAI/SCCT/SCMR 2008 appropriateness criteria for stress echocardiography [J].
Douglas, Pamela S. ;
Khandheria, Bijoy ;
Stainback, Raymond F. ;
Weissman, Neil J. .
CIRCULATION, 2008, 117 (11) :1478-1497
[6]   ACCF/ASE/ACEP/ASNC/SCAI/SCCT/SCMR 2007 appropriateness criteria for transthoracic and transesophageal echocardiography [J].
Douglas, Pamela S. ;
Khandheria, Bijoy ;
Stainback, Raymond F. ;
Weissman, Neil J. ;
Brindis, Ralph G. ;
Patel, Manesh R. ;
Khandheria, Bijoy ;
Alpert, Joseph S. ;
Fitzgerald, David ;
Heidenreich, Paul ;
Martin, Edward T. ;
Messer, Joseph V. ;
Miller, Alan B. ;
Picard, Michael H. ;
Raggi, Paolo ;
Reed, Kim D. ;
Rumsfeld, John S. ;
Steimle, Anthony E. ;
Torkovic, Russ ;
Vijayaraghavan, Krishnaswami ;
Weissman, Neil J. ;
Yeon, Susan Bok ;
Brindis, Ralph G. ;
Douglas, Pamela S. ;
Hendel, Robert C. ;
Patel, Manesh R. ;
Peterson, Eric ;
Wolk, Michael J. ;
Allen, Joseph M. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (07) :787-805
[7]   ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography [J].
Douglas, Pamela S. ;
Garcia, Mario J. ;
Haines, David E. ;
Lai, Wyman W. ;
Manning, Warren J. ;
Patel, Ayan R. ;
Picard, Michael H. ;
Polk, Donna M. ;
Ragosta, Michael ;
Ward, R. Parker ;
Weiner, Rory B. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (03) :229-267
[8]   Application of Appropriateness Criteria in Outpatient Transthoracic Echocardiography [J].
Kirkpatrick, James N. ;
Ky, Bonnie ;
Rahmouni, Hind W. ;
Chirinos, Julio A. ;
Farmer, Steven A. ;
Fields, Anjali V. ;
Ogbara, Jeffrey ;
Eberman, Karen M. ;
Ferrari, Victor A. ;
Silvestry, Frank E. ;
Keane, Martin G. ;
Opotowsky, Alexander R. ;
Sutton, Martin St. John ;
Wiegers, Susan E. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) :53-59
[9]   Recommendations for chamber quantification: A report from the American Society of Echocardiography's guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology [J].
Lang, RM ;
Bierig, M ;
Devereux, RB ;
Flachskampf, FA ;
Foster, E ;
Pellikka, PA ;
Picard, MH ;
Roman, MJ ;
Seward, J ;
Shanewise, JS ;
Solomon, SD ;
Spencer, KT ;
Sutton, MS ;
Stewart, WJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1440-1463
[10]   Evaluation of the Clinical Application of the ACCF/ASE Appropriateness Criteria for Stress Echocardiography [J].
Mansour, Ibrahim N. ;
Lang, Roberto M. ;
Aburuwaida, Waseem M. ;
Bhave, Nicole M. ;
Ward, R. Parker .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (11) :1199-1204