Electrochemical magnetoimmunosensing strategy for the detection of pesticides residues

被引:121
作者
Zacco, E
Pividori, MI [1 ]
Alegret, S
机构
[1] Univ Barcelona, Dept Analyt Chem, Barcelona 08028, Catalonia, Spain
[2] Autonomous Univ Barcelona, Sensors & Biosensors Grp, Div Analyt Chem, Dept Chem, Bellaterra 08193, Catalonia, Spain
[3] Univ Nacl Litoral, Fac Bioquim & Ciencias Biol, Santa Fe, Argentina
关键词
D O I
10.1021/ac0512610
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical immunosensing strategy for the detection of atrazine based on magnetic beads is presented. Different coupling strategies for the modification of the magnetic beads with the specific anti-atrazine antibody have been developed. The immunological reaction for the detection of atrazine performed on the magnetic bead is based on a direct competitive assay using a peroxidase (HRP) tracer as the enzymatic label. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magnetosensor made of graphite-epoxy composite, which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate and mediator for the enzyme HRP. The electrochemical approach is also compared with a novel magneto-ELISA based on optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked real orange juice samples. The detection limit for atrazine using the competitive electrochemical magnetoimmunosensing strategy with anti-atrazine-specific antibody covalent coupled with tosyl-activated magnetic beads was found to be 6 x 10(-3) mu g L-1 (0.027 nmol L-1). This strategy offers great promise for rapid, simple, cost-effective, and on-site analysis of biological, food, and environmental samples.
引用
收藏
页码:1780 / 1788
页数:9
相关论文
共 27 条
[1]  
ALEGRET S, 2003, COMPREHENSIVE ANAL C, V34, pCH1
[2]   Evaluation of a field-test kit for triazine herbicides (Se nsioScreen® TR500) as a fast assay to detect pesticide contamination in water samples [J].
Ballesteros, B ;
Barceló, D ;
Dankwardt, A ;
Schneider, P ;
Marco, MP .
ANALYTICA CHIMICA ACTA, 2003, 475 (1-2) :105-115
[3]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[4]   DETERMINATION OF ATRAZINE RESIDUES IN FOOD BY ENZYME-IMMUNOASSAY [J].
BUSHWAY, RJ ;
PERKINS, B ;
SAVAGE, SA ;
LEKOUSI, SL ;
FERGUSON, BS .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1989, 42 (06) :899-904
[5]   Gas chromatography/ion trap mass spectrometry applied for the anal sis of triazine herbicides in environmental waters by an isotope dilution technique [J].
Cai, ZW ;
Wang, DL ;
Ma, WT .
ANALYTICA CHIMICA ACTA, 2004, 503 (02) :263-270
[6]   New materials for electrochemical sensing .1. Rigid conducting composites [J].
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :296-304
[7]   Development of a highly sensitive enzyme-linked immunosorbent assay for atrazine - Performance evaluation by flow injection immunoassay [J].
Gascon, J ;
Oubina, A ;
Ballesteros, B ;
Barcelo, D ;
Camps, F ;
Marco, MP ;
GonzalezMartinez, MA ;
Morais, S ;
Puchades, R ;
Maquieira, A .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :149-162
[8]  
Heelan B, 2000, METH MOLEC MED, V40, P281, DOI 10.1385/1-59259-076-4:281
[9]   Characterization of DNA probes immobilized on gold surfaces [J].
Herne, TM ;
Tarlov, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (38) :8916-8920
[10]   PROTEIN A FROM STAPHYLOCOCCUS-AUREUS - ITS ISOLATION BY AFFINITY CHROMATOGRAPHY AND ITS USE AS AN IMMUNOSORBENT FOR ISOLATION OF IMMUNOGLOBULINS [J].
HJELM, H ;
HJELM, K ;
SJOQUIST, J .
FEBS LETTERS, 1972, 28 (01) :73-&