Aptamer-Based Origami Paper Analytical Device for Electrochemical Detection of Adenosine

被引:289
作者
Liu, Hong [1 ]
Xiang, Yu [2 ]
Lu, Yi [2 ]
Crooks, Richard M. [1 ]
机构
[1] Univ Texas Austin, Dept Chem & Biochem, Ctr Electrochem, Austin, TX 78712 USA
[2] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
基金
美国国家卫生研究院;
关键词
aptamers; biosensors; current amplification; electrochemistry; paper fluidic devices; SENSORS; DNA; MICROFLUIDICS; BIOSENSORS; PLATFORM; POINT;
D O I
10.1002/anie.201202929
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Paper biosensors: An origami sensor is printed on a single piece of paper, folded into a three-dimensional fluidic device, and encapsulated by thermal lamination. Aptamer is trapped in the fluidic channel, where it binds to the target and releases an enzyme to generate a signal. The device is read out using a digital multimeter. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:6925 / 6928
页数:4
相关论文
共 34 条
[1]   Activated Paper Surfaces for the Rapid Hybridization of DNA through Capillary Transport [J].
Araujo, Ana Catarina ;
Song, Yajing ;
Lundeberg, Joakim ;
Stahl, Patrik L. ;
Brumer, Harry, III .
ANALYTICAL CHEMISTRY, 2012, 84 (07) :3311-3317
[2]   Applications of Aptamers as Sensors [J].
Cho, Eun Jeong ;
Lee, Joo-Woon ;
Ellington, Andrew D. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2009, 2 :241-264
[3]  
Davies R. J., 2008, HDB BIOSENSORS BIOCH
[4]   Electrochemical Detection for Paper-Based Microfluidics [J].
Dungchai, Wijitar ;
Chailapakul, Orawon ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5821-5826
[5]   Multiplex Lateral-Flow Test Strips Fabricated by Two-Dimensional Shaping [J].
Fenton, Erin M. ;
Mascarenas, Monica R. ;
Lopez, Gabriel P. ;
Sibbett, Scott S. .
ACS APPLIED MATERIALS & INTERFACES, 2009, 1 (01) :124-129
[6]   Controlled reagent transport in disposable 2D paper networks [J].
Fu, Elain ;
Lutz, Barry ;
Kauffman, Peter ;
Yager, Paul .
LAB ON A CHIP, 2010, 10 (07) :918-920
[7]   Point of Care Diagnostics: Status and Future [J].
Gubala, Vladimir ;
Harris, Leanne F. ;
Ricco, Antonio J. ;
Tan, Ming X. ;
Williams, David E. .
ANALYTICAL CHEMISTRY, 2012, 84 (02) :487-515
[8]   A DNA APTAMER THAT BINDS ADENOSINE AND ATP [J].
HUIZENGA, DE ;
SZOSTAK, JW .
BIOCHEMISTRY, 1995, 34 (02) :656-665
[9]   Self-powered enzyme-based biosensors [J].
Katz, E ;
Bückmann, AF ;
Willner, I .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (43) :10752-10753
[10]   Target-Responsive Structural Switching for Nucleic Acid-Based Sensors [J].
Li, Di ;
Song, Shiping ;
Fan, Chunhai .
ACCOUNTS OF CHEMICAL RESEARCH, 2010, 43 (05) :631-641