Harmonic imaging: echocardiographic enhanced contrast intensity and duration

被引:16
作者
Allen, MR [1 ]
Pellikka, PA [1 ]
Villarraga, HR [1 ]
Klarich, KW [1 ]
Foley, DA [1 ]
Mulvagh, SL [1 ]
Seward, JB [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1999年 / 15卷 / 03期
关键词
contrast echocardiography; contrast media; harmonic imaging; left ventricular cavity;
D O I
10.1023/A:1006140102056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The intensity and duration of contrast effect within the left ventricular cavity after an intravenous bolus of Levovist Injection were observed with both harmonic and fundamental imaging in nine patients with known or suspected coronary artery disease. Contrast intensity was assessed by a qualitative grading system (0, none; 1, weak; 2, moderate; 3, good) and by videodensitometric analysis of pixel intensity. Duration of left ventricular contrast effect was determined by measuring time from the initial visual appearance of contrast agent to its disappearance. The mean increase in pixel intensity within the left ventricular cavity from precontrast to peak contrast was significantly greater for second harmonic than for fundamental imaging (25.5 vs 7.1; P < 0.012). The mean contrast intensity qualitative score with harmonic imaging was higher (2.6 +/- 0.73 vs 1.2 +/- 0.44; P < 0.01) and the duration of contrast effect was longer (242 +/- 131 s vs 53 +/- 33 s; P < 0.004). Second harmonic imaging significantly enhanced contrast intensity and prolonged visible duration of contrast effect after a peripheral venous injection of Levovist.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 14 条
[1]  
BECKMANN S, 1993, Z KARDIOL, V82, P317
[2]   PRINCIPLES AND RECENT DEVELOPMENTS IN ULTRASOUND CONTRAST AGENTS [J].
DEJONG, N ;
TENCATE, FJ ;
LANCEE, CT ;
ROELANDT, JRTC ;
BOM, N .
ULTRASONICS, 1991, 29 (04) :324-330
[3]  
FIRSCHKE C, 1994, CIRCULATION, V90, P68
[4]  
MIYATAKE K, 1995, J AM COLL CARDIOL, V25, pA205
[5]   Second harmonic imaging of an intravenously administered echocardiographic contrast agent - Visualization of coronary arteries and measurement of coronary blood flow [J].
Mulvagh, SL ;
Foley, DA ;
Aeschbacher, BC ;
Klarich, KK ;
Seward, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1519-1525
[6]   Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging [J].
Porter, TR ;
Li, SP ;
Kricsfeld, D ;
Armbruster, RW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (04) :791-799
[7]   Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin [J].
Porter, TR ;
Xie, F ;
Kricsfeld, D ;
Armbruster, RW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1497-1501
[8]  
Schlief R, 1990, Echocardiography, V7, P61, DOI 10.1111/j.1540-8175.1990.tb00349.x
[9]  
Schroder K, 1994, Int J Card Imaging, V10, P45, DOI 10.1007/BF01151580
[10]   2ND-HARMONIC ULTRASONIC BLOOD PERFUSION MEASUREMENT [J].
SCHROPE, BA ;
NEWHOUSE, VL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (07) :567-579