Quantitation of benzodiazepine receptor binding with PET [11C]iomazenil and SPECT [123I]iomazenil:: preliminary results of a direct comparison in healthy human subjects

被引:18
作者
Bremner, JD
Baldwin, R
Horti, A
Staib, LH
Ng, CK
Tan, PZ
Zea-Ponce, Y
Zoghbi, S
Seibyl, JP
Soufer, R
Charney, DS
Innis, RB
机构
[1] VA Conn Healthcare Syst, Yale VA PET Ctr 115A, W Haven, CT 06516 USA
[2] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
[3] Yale Univ, Sch Med, Dept Psychiat, New Haven, CT 06520 USA
[4] VA Connecticut Healthcare Syst, Psychiat Serv, W Haven, CT 06516 USA
[5] VA Connecticut Healthcare Syst, Natl Ctr PTSD, W Haven, CT 06516 USA
关键词
positron emission tomography; single photon emission computed tomography; benzodiazepine receptor binding; compartmental modeling; kinetic rate constants; methodology;
D O I
10.1016/S0925-4927(99)00015-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Although positron emission tomography (PET) and single photon emission computed tomography (SPECT) are increasingly used for quantitation of neuroreceptor binding, almost no studies to date have involved a direct comparison of the two. One study found a high level of agreement between the two techniques, although there was a systematic 30% increase in measures of benzodiazepine receptor binding in SPECT compared with PET. The purpose of the current study was to directly compare quantitation of benzodiazepine receptor binding in the same human subjects using PET and SPECT with high specific activity [C-11]iomazenil and [I-123]iomazenil, respectively. All subjects were administered a single bolus of high specific activity iomazenil labeled with C-11 or I-123 followed by dynamic PET or SPECT imaging of the brain. Arterial blood samples were obtained for measurement of metabolite-corrected radioligand in plasma. Compartmental modeling was used to fit values for kinetic rate constants of transfer of radioligand between plasma and brain compartments. These values were used for calculation of binding potential (BP = B-max/K-d) and product of BP and the fraction of free non-protein-bound parent compound (V3'). Mean values for V3' in PET and SPECT were as follows: temporal cortex 23 +/- 5 and 22 +/- 3 ml/g, frontal cortex 23 +/- 6 and 22 +/- 3 ml/g, occipital cortex 28 +/- 3 and 31 +/- 5 ml/g, and striatum 4 +/- 4 and 7 +/- 4 ml/g. These preliminary findings indicate that PET and SPECT provide comparable results in quantitation of neuroreceptor binding in the human brain. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:79 / 91
页数:13
相关论文
共 24 条
  • [1] CENTRAL BENZODIAZEPINE RECEPTORS IN HUMAN BRAIN - ESTIMATION OF REGIONAL B(MAX) AND K(D) VALUES WITH POSITRON EMISSION TOMOGRAPHY
    ABADIE, P
    BARON, JC
    BISSERBE, JC
    BOULENGER, JP
    RIOUX, P
    TRAVERE, JM
    BARRE, L
    PETITTABOUE, MC
    ZARIFIAN, E
    [J]. EUROPEAN JOURNAL OF PHARMACOLOGY, 1992, 213 (01) : 107 - 115
  • [2] ABI-DARGHAM A, 1995, J NUCL MED, V36, P167
  • [3] ABI-DARGHAM A, 1994, J NUCL MED, V35, P228
  • [4] BAILEY DL, 1994, EUR J NUCL MED, V21, P381
  • [5] SYNTHESIS AND PET IMAGING OF THE BENZODIAZEPINE RECEPTOR TRACER [N-METHYL-C-11]IOMAZENIL
    BALDWIN, RM
    HORTI, AG
    BREMNER, JD
    STRATTON, MD
    DANNALS, RF
    RAVERT, HT
    ZEAPONCE, Y
    NG, CK
    DEY, HM
    SOUFER, R
    CHARNEY, DS
    MAZZA, SM
    SPARKS, RB
    STUBBS, JB
    INNIS, RB
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 1995, 22 (05): : 659 - 665
  • [6] BEER HF, 1990, J NUCL MED, V31, P1007
  • [7] Buck A, 1996, J NUCL MED, V37, P699
  • [8] CARSON RE, 1991, J NUCL MED, V32, P2206
  • [10] EVALUATION OF ULTRAFILTRATION FOR THE FREE-FRACTION DETERMINATION OF SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY (SPECT) RADIOTRACERS - BETA-CIT, IBF, AND IOMAZENIL
    GANDELMAN, MS
    BALDWIN, RM
    ZOGHBI, SS
    ZEAPONCE, Y
    INNIS, RB
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (07) : 1014 - 1019