The impedance of stimulating electrodes used in cochlear implants and other neural prostheses often increases post-implantation, and is thought to be due to fibrous tissue encapsulation of the electrode array. Increased impedance results in higher power requirements to stimulate target neurons at set charge densities. We developed an in vitro model to investigate the electrode-tissue interface in a highly controlled environment. This model was tested using three cell types, with and without charge-balanced biphasic electrical stimulation. Under standard tissue culture conditions, a monolayer of cells was grown over the electrode surface. Electrode impedance increased in proportion to the extent of cell coverage of the electrode. Cell type was a significant factor in the amount of impedance increase, with kidney epithelial cells (MDCK) creating the greatest impedance, followed by dissociated rat skin fibroblasts and then macrophages (J774). The application of electrical stimulation to cell-covered electrodes caused impedance fluctuations similar to that seen in vivo, with a lowering of impedance immediately following stimulation, and a recovery to pre-stimulation levels during inactive periods. Examination of these electrodes suggests that the stimulation-induced impedance changes were due to the amount of cell cover over the electrodes. This in vitro technique accurately models the changes in impedance observed with neural prostheses in vivo, and shows the close relationship between impedance and tissue coverage adjacent to the electrode surface. We believe that this in vitro approach holds great promise to further our knowledge of the mechanisms contributing to electrode impedance.
引用
收藏
页码:218 / 227
页数:10
相关论文
共 39 条
[1]   Biological responses to materials [J].
Anderson, JM .
ANNUAL REVIEW OF MATERIALS RESEARCH, 2001, 31 :81-110
[2]  
Anderson JM, 1994, PROB GEN SURG, V11, P147
[3]   CORTICAL HISTOPATHOLOGY FOLLOWING STIMULATION WITH METALLIC AND CARBON ELECTRODES [J].
BERNSTEIN, JJ ;
JOHNSON, PF ;
HENCH, LL ;
HUNTER, G ;
DAWSON, WW .
BRAIN BEHAVIOR AND EVOLUTION, 1977, 14 (1-2) :126-157
[4]   ADVANTAGES OF USING MICROFABRICATED EXTRACELLULAR ELECTRODES FOR IN-VITRO NEURONAL RECORDING [J].
BRECKENRIDGE, LJ ;
WILSON, RJA ;
CONNOLLY, P ;
CURTIS, ASG ;
DOW, JAT ;
BLACKSHAW, SE ;
WILKINSON, CDW .
JOURNAL OF NEUROSCIENCE RESEARCH, 1995, 42 (02) :266-276
[5]  
Busby P A, 2002, Cochlear Implants Int, V3, P87, DOI 10.1179/cim.2002.3.2.87
[6]   Rapid differentiation of fermentative from nonfermentative gram-negative bacilli in positive blood cultures by an impedance method [J].
Chang, TC ;
Huang, AH .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (10) :3589-3594
[7]  
Clark G M, 1984, Acta Otolaryngol Suppl, V410, P1
[8]  
Clark G M, 1995, Ann Otol Rhinol Laryngol Suppl, V166, P40
[9]   Electrical and physiological changes during short-term and chronic electrical stimulation of the normal cochlea [J].
deSauvage, RC ;
daCosta, DL ;
Erre, JP ;
Aran, JM .
HEARING RESEARCH, 1997, 110 (1-2) :119-134
[10]   FACTORS INFLUENCING THE BIOCOMPATIBILITY OF INSERTABLE SILICON MICROSHAFTS IN CEREBRAL-CORTEX [J].
EDELL, DJ ;
TOI, VV ;
MCNEIL, VM ;
CLARK, LD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :635-643